Belden process instrumentation cables
Belden HART Cable
Belden shielded twisted-pair cables for HART field devices. Pick the conductor size, the pair count and the jacket for your plant, then send us the code and the length.
- Shielded twisted pair
- 22 and 24 AWG
- PVC, LSZH, direct burial
- Armoured versions
- Common types in stock
- Cut lengths
We keep commonly used types in stock and supply cut lengths as well as full reels. We ship worldwide from our warehouses in Germany and Turkey.
Request a quote by part number Help me choose the right cable

Quick selection: HART cable by installation
Five codes cover most HART requests.
| Belden code | Construction | Typical choice when | Quote |
|---|---|---|---|
| 9841 | 1 pair, 24 AWG, PVC | A single instrument loop indoors | Request a quote |
| 3105A | 1 pair, 22 AWG, PVC | Longer runs or a larger conductor is preferred | Request a quote |
| 3107Z | 2 pairs, 22 AWG, LSZH | Halogen-free jacket is specified | Request a quote |
| 3105DB | 1 pair, 22 AWG, direct burial | The cable is laid in the ground | Request a quote |
| 123105A | 1 pair, 22 AWG, aluminium armour | Mechanical protection without conduit | Request a quote |
Tell us the device type, the loop length and the environment if you would like us to suggest the code.
All Belden HART cable codes
The 41 codes Belden currently lists for HART, grouped by construction.
| Belden code | Construction (Belden short description) |
|---|---|
| 22 AWG shielded pairs: PVC, direct burial and LSZH (17) | |
| 3105A | RS-485, 1 Pr, 22AWG, Str TC, PE Ins, OS+TC Brd, PVC Jkt, CM, PLTC, Sun Res, Oil Resistant |
| 3105DB | RS-485, 1 Pr, 22AWG, Str TC, PE Ins, OS+TC Brd, CPE Jkt, CM, PLTC, Sun Res, Dir Bur, Oil Resistant |
| 3105T | RS-485, 1 Pr, 22AWG, Str TC, PE Ins, OS+TC Brd, LSZH Jkt, CMG-ST1, PLTC, Sun Res |
| 3105Z | RS-485, 1 Pr, 22AWG, Str TC, PE Ins, OS+TC Brd, LSZH-TS Jkt, CMG, PLTC, Sun Res |
| 3106A | RS-485, 1 Pr, 22AWG, Str TC, PE Ins, with OS, 1C 22AWG Str, PVC Ins, OA TC Brd, PVC Jkt, CM, PLTC, Sun Res, Oil Resistant |
| 3106DB | RS-485, 1 Pr, 22AWG, Str TC, PE Ins, with OS, 1 c #22AWG Str, PVC Ins, OA TC Brd, CPE Jkt, CM, PLTC, Sun Res, Dir Bur, Oil Resistant |
| 3107DB | RS-485, 2 Pr, 22AWG, Str TC, PE Ins, OS+TC Brd, CPE Jkt, CM, PLTC, Sun Res, Dir Bur, Oil Resistant |
| 3107T | RS485, 2 Pr #22 Str TC, PE Ins, OS+TC Brd, LSZH Jkt, CMG |
| 3107Z | RS485, 2 Pr #22 Str TC, PE Ins, OS+TC Brd, LSZH-TS Jkt, CMG |
| 3108A | RS485, 3 Pr #22 Str TC, PE Ins, OS+TC Brd, PVC Jkt, CM, PLTC, Oil Resistant |
| 3108DB | RS-485, 3 Pr, 22AWG, Str TC, PE Ins, OS+TC Brd, CPE Jkt, CM, PLTC, Sun Res, Dir Bur, Oil Resistant |
| 3108T | RS485, 3 Pr #22 Str TC, PE Ins, OS+TC Brd, LSZH Jkt, CMG, PLTC |
| 3108Z | RS485, 3 Pr #22 Str TC, PE Ins, OS+TC Brd, LSZH-TS Jkt, CMG, PLTC |
| 3109A | RS485, 4 Pr #22 Str TC, PE Ins, OS+TC Brd, PVC Jkt, CM, PLTC, Oil Resistant |
| 3109DB | RS-485, 4 Pr, 22AWG, Str TC, PE Ins, OS+TC Brd, CPE Jkt, CM, PLTC, Sun Res, Dir Bur, Oil Resistant |
| 3109T | RS485, 4 Pr #22 Str TC, PE Ins, OS+TC Brd, LSZH Jkt, CMG, PLTC |
| 3109Z | RS485, 4 Pr #22 Str TC, PE Ins, OS+TC Brd, LSZH-TS Jkt, CMG, PLTC |
| 24 AWG shielded pairs: PVC, LSZH and plenum (9) | |
| 9841 | RS485, 1 Pr #24 Str TC, PE Ins, OS+TC Brd, PVC Jkt, CM |
| 9841ZH | RS485, 1 Pr #24 Str TC, PE Ins, OS+TC Brd, LSZH Jkt, CM |
| 9842 | RS485, 2 Pr #24 Str TC, PE Ins, OS+TC Brd, PVC Jkt, CM |
| 9843 | RS485, 3 Pr #24 Str TC, PE Ins, OS+TC Brd, PVC Jkt, CM |
| 9844 | RS485, 4 Pr #24 Str TC, PE Ins, OS+TC Brd, PVC Jkt, CM |
| 82841 | RS485, 1 Pr #24 Str TC, FEP Ins, OS+TC Brd, PVC Jkt, CMP |
| 82842 | RS485, 2 Pr #24 Str TC, FEP Ins, OS+TC Brd, PVC Jkt, CMP |
| 89841 | RS485, 1 Pr #24 Str TC, FEP Ins, OS+TC Brd, FEP Jkt, CMP |
| 89842 | RS485, 2 Pr #24 Str TC, FEP Ins, OS+TC Brd, FEP Jkt, CMP |
| Armoured 22 AWG pairs: aluminium or steel interlock (10) | |
| 123105A | RS-485, 1 Pr, 22AWG, Str TC, PE Ins, OS+TC Brd, PVC Jkt, AIA, PVC Jkt, CM, PLTC, Sun Res |
| 123106A | RS-485, 1 Pr, 22AWG, Str TC, PE Ins, with OS, 1C 22AWG Str, PVC Ins, OA TC Brd, PVC Jkt, AIA, PVC Jkt, CM, PLTC, Sun Res |
| 123107A | RS485, 2 Pr #22 Str TC, PE Ins, OS+TC Brd, PVC Jkt, AIA Armor, PVC Jkt, CM, PLTC |
| 123108A | RS485, 3 Pr #22 Str TC, PE Ins, OS+TC Brd, PVC Jkt, AIA Armor, PVC Jkt, CMG, PLTC |
| 123109A | RS485, 4 Pr #22 Str TC, PE Ins, OS+TC Brd, PVC Jkt, AIA Armor, PVC Jkt, CM, PLTC |
| 133105A | RS-485, 1 Pr, 22AWG, Str TC, PE Ins, OS+TC Brd, PVC Jkt, SIA, PVC Jkt, CM, PLTC, Sun Res |
| 133106A | RS-485, 1 Pr, 22AWG, Str TC, PE Ins, with OS, 1C 22AWG Str, PVC Ins, OA TC Brd, PVC Jkt, SIA, PVC Jkt, CM, PLTC, Sun Res |
| 133107A | RS485, 2 Pr #22 Str TC, PE Ins, OS+TC Brd, PVC Jkt, SIA Armor, PVC Jkt, CM, PLTC |
| 133108A | RS485, 3 Pr #22 Str TC, PE Ins, OS+TC Brd, PVC Jkt, SIA Armor, PVC Jkt, CM, PLTC |
| 133109A | RS485, 4 Pr #22 Str TC, PE Ins, OS+TC Brd, PVC Jkt, SIA Armor, PVC Jkt, CM, PLTC |
| MachFlex flexible pairs (4) | |
| 7200A | MachFlex™, 1 Pr #24 Str BC, PO Ins, OS+TC Brd, PVC Jkt, CM |
| 7201A | MachFlex™, 2 Pr #24 Str BC, PO Ins, OS+TC Brd, PVC Jkt, CM |
| 7202A | MachFlex™, 3 Pr #24 Str BC, PO Ins, OS+TC Brd, PVC Jkt, CM |
| 7203A | MachFlex™, 4 Pr #24 Str BC, PE Ins, OS+TC Brd, PVC Jkt, CM |
| DataTray twinax (1) | |
| 3074F | DataTray® 120Ω Twinax, 1 Pr #18 Str TC, PP Ins, OS+TC Brd, PVC Jkt, TC, PLTC, ITC, CMG |
Constructions are given in Belden catalogue shorthand: Pr = pair, C = conductor, Str = stranded, Sol = solid, TC = tinned copper, BC = bare copper, OS = overall shield, IS = individual shield, Brd = braid, Ins = insulation, Jkt = jacket.
What a HART cable has to do
HART adds a digital signal on top of the 4–20 mA analogue loop, so configuration and diagnostic data travel over the same pair as the measurement. The cable therefore has to carry the analogue current and keep the digital signal clean.
Why shielded twisted pair?
Twisting and shielding keep electrical noise away from the signal on long runs through a plant. Belden lists individually shielded pairs with foil and braid for this.
How many pairs?
One pair serves one loop. Multi-pair cable carries several loops in one run to a junction box or cabinet.
Which jacket?
PVC for general indoor use, LSZH where low smoke and no halogen is required, direct burial types for laying in the ground, and armoured types where the cable runs without conduit.
Why Belden?
- Shielded pairs with foil and braid for noise protection on long runs
- 22 and 24 AWG, from 1 to 4 pairs
- PVC, LSZH, plenum and direct burial jackets
- Aluminium and steel interlock armoured versions
- A datasheet for each code on belden.com
Why PROTEL?
- Authorised Belden distributor. Products come directly from the manufacturer.
- Stock. Commonly used types are kept in stock.
- Cut lengths. You do not have to buy a full reel.
- Selection support. Tell us your line and devices; we recommend a type and explain why.
- Worldwide supply. Shipped from our warehouses in Germany and Turkey.
Frequently asked questions
Which Belden cable is used for HART?
Belden lists its shielded twisted-pair data cables for HART, mainly the 9841 family in 24 AWG and the 3105A family in 22 AWG, with LSZH, direct burial and armoured versions.
Can I keep the existing 4–20 mA cabling for HART?
HART was designed to run on 4–20 mA loops. Whether an existing cable is suitable depends on its length, capacitance and shielding; send us the cable type and the loop length and we will compare it with the Belden datasheets.
Is there a halogen-free HART cable?
Yes. The T and Z versions of the 3105 to 3109 series and 9841ZH have LSZH jackets.
Do I have to buy a full reel?
No. We supply cut lengths. The part number and the total length are enough.
Request a quote
- If you know the code: the part number, total length and delivery country are enough.
- If you do not: send your application, line length and environment; we recommend the type.
- If you have a specification or BOQ: send it and we will return the matching part numbers.
Product images and technical information on this page are © Belden Inc. and are used with the manufacturer’s permission. Technical values are taken from the manufacturer’s datasheets; the current datasheet is binding. Source: belden.com
Call us for more information.
Consult PROTEL experts for more details, technical information and routing assistance regarding BELDEN cables.