Belden optical fiber cable

Belden Optical Fiber Cables

As Belden’s general distributor for Turkey we supply the entire Belden fiber optic cable range — both the European and the American production lines. Belden has merged its former European catalogue into the single global catalogue; on this page you will find the current family structure together with the old European part-code equivalents.

  • Central loose tube
  • Multi-loose tube
  • Ribbon
  • Breakout
  • Distribution
  • Armored
  • Hybrid copper-fiber
  • Tactical
With a part number this is quick

Belden has around 500 fiber cable types. Send us the part number and we will price it directly. If you do not have one, describe the route and the environment and we will pick the right code for you. If you need short lengths or a shorter lead time, see the manufacturer comparison on our fiber optic cable page .

Request a quote Ask on WhatsApp

Which Belden family?

Where it is used Belden family Cores Fiber
Duct, direct burial, aerial Central Loose Tube 2–24 OM3–OM5, OS2 (G.657A1/A2/B3)
High-count outdoor backbone Multi-Loose Tube 12–144 OM1–OM5, OS2
Data center, very high density Ribbon 12–1728 SM and MM
Building backbone, vertical and horizontal distribution Distribution Tight Buffer 2–144 OM1, OM3–OM5, OS2
Pre-terminated indoor runs with MPO Mini Distribution 8–144 OM3–OM5, OS2
Ends connectorized directly in the field Breakout 2–18 OM1, OM3–OM5, OS2
High-density patching inside the cabinet Interconnect 1–12 OM1, OM3–OM5, OS2
Alternative to metal armor, tight pathways OptiTuff Mini 6, 12, 24 OM4, OS2
Portable use, repeated deployment and recovery Tactical 2–24 SM and MM
HD camera, stadium, broadcast SMPTE hybrid camera cable 2 fibers + copper SM
Data and DC power in one cable DuetConnect hybrid copper-fiber 1–6 fibers + 2 conductors OM3–OM5, OS2
High power over long distance FMPS / Digital Electricity Hybrid SM and MM

The families in the table follow Belden’s current structure. If your specification is written with the old European codes (GUSN, GOSN, GBRG and the like), the cards below give the equivalents; you can also order those codes directly.

Outdoor and backbone cables

For duct, direct burial, aerial routes and campus backbone. Gel-filled and dry constructions; unarmored, corrugated steel tape armored (CST) and steel wire armored (SWA) options.

Belden central loose tube fiber optic cable cross-section — GUSN, GUSL, GURN, GUVN

Central loose tube

Central Loose Tube

All fibers in a single central tube. 2–24 cores, 250 µm fiber. Rodent protection at 1.5 kN, 3.15 kN and 4.5 kN levels; metal-free, CST armored and double-sheathed steel wire armored versions are available.

Fiber: OM3, OM4, OM5; OS2 G.657A1, G.657A2, G.657B3

Where: campus backbone, telecom and cable TV networks, blown installation with compressed air

Code families: GOSMD, GORMD, GOVMD, GOCMD, GOWMD · old European: GUSN, GUSL, GURN, GUVN, GOSN, GORN, GOVN, GMSN, GUCN, GUCB, GOCN, GOCB, GUDN, GUDB, GODN, GODB, GUHA, GOHN, GUWN, GUWB, GOWN, GOWB, GUFN, GUFB, GOFN, GOFB

Belden multi-loose tube fiber optic cable cross-section — GCRG, GCRD, GCRE, GCRF

Multi-loose tube

Multi-Loose Tube (MLT)

Fibers split across several tubes; high core count and easy separation. 12–144 cores. Gel-filled and dry versions; metal-free, CST and SWA armor options.

Fiber: OM1–OM5; OS2 G.657A1, G.657A2, G.657B3

Where: duct, direct burial, aerial; RailTuff for rail, DataTuff for mining

Code families: GBROD, GBROE, GBROC, GBCOD, GBWOD, GBRH, GBRI · old European: GCRG, GCRD, GCRE, GCRF, GBRG, GBRD, GBRE, GBRF, GDRG, GDRD, GDRE, GDRF, GCCG, GCCD, GBCG, GBCD, GCDG, GCDD, GBDG, GBDD, GCWG, GCWD, GBWG, GBWD, GDWG, GDWD

Belden ribbon fiber optic cable family

Ribbon

Ribbon fiber

Fibers held in ribbon form, so a whole ribbon is mass-fusion spliced in one go. 12–1728 cores. No preferential bend axis, so it pulls easily through tight pathways.

Fire rating: CMP and CMR / CMR-LS 12–288; CMR 12–1728; indoor-outdoor CMR

Where: 40G and 100G data centers, high-count backbone

Aerial, tactical and special environments

Belden ADSS aerial fiber optic cable cross-section — GAAG, GAAD, GAAE

ADSS aerial cable

All-Dielectric Self-Supporting

Metal-free aerial cable that carries itself without a messenger wire. Designed for a free span between poles; because it contains no conductive part it is also used along power transmission routes.

Where: pole-to-pole spans, routes alongside power lines, campus links

Code families: GAAG, GAAD, GAAE

Belden wind turbine fiber optic cable cross-section — GWRT

Wind turbine cable

Vertically suspended installation

Flexible cable for vertical suspended mounting inside a turbine tower; built to carry its own weight and to withstand vibration.

Where: wind farms, vertical shafts in tall structures

Code families: GWRT

Belden tactical fiber optic cable cross-section — GMTT

Tactical cable

Tactical

900 µm tight-buffered cable designed to be unreeled and rewound many times. UV-resistant jacket, high crush resistance. MaxiBend variant for harsh sites.

Where: military communications, outside broadcast (OB), sports events, temporary installations

Code families: GMTT, GMRT, GMBT

Indoor cables

Building backbone, floor distribution and in-cabinet links. If the specification states a fire rating, say so with your enquiry; plenum (OFNP), riser (OFNR) and LSZH versions are separate part numbers.

Belden distribution tight buffer fiber optic cable family

Distribution cable

Distribution · Tight buffer

900 µm tight-buffered fiber for fast field termination. 2–144 cores, subunit and non-subunit versions, interlocking aluminum armor option.

Ratings: OFNP, OFNR, LSZH · factory (TF), marine (TM), rail (TT), cable tray (TU) classes

Where: building backbone, vertical and horizontal cabling, enterprise networks

Code families: FI, TF, TM, TT, TU

Belden mini distribution fiber optic cable family

Mini distribution

Mini Distribution

250 µm subunit construction, suited to MPO termination and thinner and lighter than standard distribution. The 2–3 mm subunits route easily through tight pathways. Base-12 (12, 24, 36, 48, 72, 144) and Base-8 (8, 16, 24, 32, 48, 64, 96) layouts.

Fiber: OM3, OM4, OM5, OS2 · Jacket: PVC, LSZH, plenum

Where: data center, labor saving through mass fusion splicing

Code families: FI3M, FI4M (indoor) · FD3M, FD4M (indoor-outdoor)

Belden breakout fiber optic cable cross-section — GIBT, GIBS

Breakout

Distribution, individually jacketed

Each fiber in its own 2 mm or 3 mm subjacket, so the ends can be connectorized directly and often need no separate termination box. Aramid yarn strength members, single and double jacket, interlocking aluminum armor or fully metal-free.

Cores: 2, 4, 6, 8, 10, 12, 18 · Fiber: OM1, OM3–OM5, OS2

Where: in duct and junction boxes, patch panels, factory floor, broadcast and AV

Code families: FI (indoor), TF, TM, TT, TU · old European: GIBT, GIBS, GUBT

Tight spaces and inside the cabinet

Belden mini breakout fiber optic cable cross-section — GUMT, GUMS

Mini breakout

Mini Breakout

The slim version of breakout; it saves space in narrow ducts and cable trays. Variants with high rodent protection, steel wire armor (SWA), corrugated steel tape armor (CST) and steel wire braid (SWB).

Where: building backbone, horizontal cabling (FTTD), in-cabinet distribution

Code families: old European: GIMT, GIMS, GUMT, GUMS, GUXT, GUXW, GUMX, GUMV

Belden interconnect fiber optic cable family

Interconnect cable

Interconnect

Simplex and duplex 900 µm tight-buffered; the mini round version carries 2–12 fibers at 250 µm. The small outside diameter makes it easy to route inside a cabinet.

Ratings: OFNP, OFNR · Fiber: OM1, OM3–OM5, OS2

Where: high-density patch areas, enterprise data centers

Belden OptiTuff Mini fiber optic cable family

OptiTuff Mini

An alternative to metal armor

A reinforced thermoplastic jacket gives the crush resistance of metal armor without the metal, so no bonding and no conduit are needed. Up to 90% lighter than armored cable, 70% smaller in diameter, with a bend radius one third that of unarmored cable.

Cores: 6, 12, 24 · Fiber: OM4, OS2

Where: FTTx and POL/PON, raised floors, crowded cable trays, hotels and commercial buildings

Code families: OptiTuff Mini · pre-terminated trunk option

Hybrid and special-purpose cables

Families that combine fiber and copper in one cable. One pull instead of separate data and power runs: less labor and fewer stock items.

Belden SMPTE hybrid camera cable family

SMPTE camera cable

SMPTE 311M / 304M

Pre-terminated hybrid cable carrying fiber and copper together for HD camera links. Machine-polished fiber contacts, soldered copper conductors, stainless steel strength member inside.

Where: HD cameras, stadium and arena installations, multi-channel (3- and 4-channel) broadcast systems

Code families: 7804 · 7824 / 7844 (stadium) · 7825 · 7817A / 7818A · suffixes: WB water-blocked, P plenum, R riser

Belden DuetConnect copper-fiber hybrid cable family

DuetConnect hybrid

Copper + fiber

DC power and fiber data in the same cable. The 2 mm breakout version carries 1–2 fibers, the 2–3 mm distribution version 2–6 fibers, plus two 12–20 AWG copper conductors.

Ratings: plenum CL3P/CMP, riser CL3R/CMR, indoor-outdoor and LSZH versions

Where: security cameras, sensors, wireless access points, IP telephones, displays

Code families: DuetConnect

Belden FMPS / Digital Electricity hybrid copper-fiber cable family

FMPS / Digital Electricity

Fault-managed power system

A hybrid copper-fiber family that carries up to 2,000 W over distances of up to 2 km. UL listed for Class 4 cabling. The transmitter and receiver monitor the line continuously and cut the power if they detect a fault.

Construction: 2–8 pairs, AWG 14–18 stranded copper; hybrid copper-fiber versions; plenum, shielded and unshielded, outdoor wet-location options

Where: DAS, PON, remote cameras and access points beyond the reach of PoE

Code families: FMPS · Digital Electricity

Fiber types and jacket ratings

Fiber Color code Where
OS2 singlemode (G.652.D, G.657A1/A2/B3) Yellow Backbone, campus, carrier network, 10 km and beyond
OM5 Lime green Short wavelength division multiplexing (SWDM), new data centers
OM4 Erika violet Data center, high speed
OM3 Aqua Data center, indoor
OM1 / OM2 Orange Additions to existing legacy infrastructure
Jacket / rating What it means Where it is asked for
OFNP / CMP Plenum: suitable for air-handling spaces Above suspended ceilings, HVAC plenums
OFNR / CMR Riser: vertical shafts between floors Building backbone
LSZH Halogen-free, low smoke Enclosed crowded spaces, metro, ships
OSP Outside plant; gel-filled or dry Duct, direct burial, aerial
Indoor-outdoor (universal) Continuous run through both environments Lines that enter from outside and continue indoors

European projects may call for a CPR class (Dca or B2ca, for example) under the construction products fire regulation. If your specification states one, say so with your enquiry — the part number changes with the class. Attenuation and bandwidth figures vary from batch to batch, so we do not publish general values here; we send the current data sheet for the selected product together with the quote.

Delivery, lengths and lead time

Topic Belden Alternative
Standard drum 1050, 2100 and 4200 m Datwyler cuts to the length you ask for
Typical lead time 4–8 weeks, imported to order PROTELFIBER 1–5 working days, Datwyler under 3 weeks
Range Around 500 fiber cable types If the specification names a Belden code, Belden directly
Shipping From our Istanbul and Germany warehouses; worldwide

Belden’s strength is the breadth of the range and its fit to written specifications. If your project names a particular Belden part number, we supply exactly that. If short lengths or fast delivery matter more to you, we put four manufacturers side by side on our fiber optic cable page — look at Datwyler there so you are not left with a part-used drum.

Belden or Datwyler?

Criterion Belden Datwyler
Length Standard drum: 1050, 2100, 4200 m Cut to any length between 100 and 8000 m, on a single drum
Typical lead time 4–8 weeks Under 3 weeks
Fire rating system North American classes (OFNP, OFNR, CMP, CMR) and LSZH Euroclass (Fca–B2ca) and E30, per product
Range Around 500 cable types in 12 families 40 cable types in three families
Strongest at Hybrid copper-fiber, SMPTE camera, FMPS power, high-count ribbon Micro cable and blown installation, E30 safety, European specifications
Specification fit North American and global specifications European specifications written to DIN codes

We are the general distributor for both, so we take no side: if the specification names a part number, we supply that manufacturer. If it does not, we suggest Belden for special constructions (hybrid, camera cable, high-count ribbon) and Datwyler for short lengths and fast delivery. On our fiber optic cable page we compare all four, PROTELFIBER and Telegärtner included.

Request a Belden fiber optic cable quote

To speed up the quote, tell us:

  • Belden part number if you have one — an old European code works too
  • Length — total length and how many pieces
  • Core count and fiber type — if you are not sure, describe the project
  • Indoor / outdoor, and whether armor is needed
  • Fire rating (CPR or OFNP/OFNR/LSZH) if the specification states one
  • Delivery place and date

E-mail: [email protected]  ·  Phone: +90 212 221 80 60  ·  WhatsApp: +90 532 265 91 99

Request a quote Compare with Datwyler

Consult us for more information.
Contact our experts for technical details and product selection support.