Fiber optic cable

Fiber Optic Cable

We supply singlemode and multimode fiber optic cable, from long-haul trunk cable to patch cords. We are the general distributor of Belden, Telegärtner and Datwyler in Turkey and can supply the complete range of all three without exception. PROTELFiBER is our own brand; we keep the common types in stock. Shipments leave from our Istanbul and Germany warehouses.

Cable cut to your length. Belden fiber optic cable comes on standard 1050, 2100 and 4200 m reels with long lead times. Datwyler cuts the cable to the length you specify and delivers it noticeably faster; a 225 m order is no problem. If you do not want part-used reels left over in your project, consider Datwyler.

If you know the part number, send it. If you do not, describe the project and we will work out the right cable type and the best manufacturer together.

  • Singlemode G.652.D
  • Multimode OM3 / OM4
  • Long-haul trunk
  • Breakout
  • Patch cord

Request a quote Ask on WhatsApp

Which cable do you need?

Application Cable type Typical cores Fiber Manufacturer and delivery
Between buildings, campus, metro Long-haul trunk (central or multi loose tube) 2–288 Singlemode G.652.D Datwyler: cut to length, under 3 weeks
Belden: standard reels, 4–8 weeks
In-building riser and horizontal, LAN Breakout distribution 4–24 SM or MM OM3/OM4 Datwyler: cut to length, under 3 weeks
Telegärtner: made to order, 4–6 weeks
Inside the rack, equipment links Patch cord 1–2 SM or MM PROTELFiBER: from stock or made to order, 1–5 working days
Data centre, high density MPO/MTP patch cord 8–72 SM or MM IRENIS: to order, MOQ applies, 3–6 weeks
Outdoor, pole, duct Armoured / UV resistant 4–144 Singlemode Datwyler or Belden
Rodent risk, harsh conditions Steel armoured 4–48 Singlemode PROTELFiBER from stock

If you need a short run or the row you are looking for is not here, describe the project through the quote form. We have access to roughly 500 Belden cable types, to Datwyler cut-to-length production and to Telegärtner made-to-order assemblies, and we build PROTELFiBER ourselves.

Long-haul trunk cable

Long-haul fiber optic trunk cable

For backbone links between buildings, across a campus and across a city. Central loose tube and multi loose tube constructions, from 2 to 288 cores.

Construction

  • Tensile strength members, metallic or all-dielectric
  • Moisture barrier, UV resistant sheath for outdoor use
  • Duct, aerial and direct burial versions
  • Steel armoured models for routes with rodent risk

Fiber options

  • Singlemode: ITU-T G.652.B and G.652.D
  • Multimode: 50/125 µm (OM3, OM4) and 62.5/125 µm (OM1)

Where it is used: carrier backbones, campus networks, plant sites, CCTV networks, and carrying satellite and RF signals over fiber.

Lengths: Datwyler cuts the cable to the length you ask for — a 225 m order is possible. Belden supplies standard reel lengths (1050, 2100, 4200 m).

Breakout distribution cable

Breakout fiber optic distribution cable

For riser and horizontal distribution inside a building. Each fiber has its own jacket, so the ends can be connectorised directly and a separate termination box may not be needed.

Construction

  • Small bending radius, easier installation in tight trunking
  • Halogen-free (LSZH) and flame-retardant sheath options
  • Common types from 4 to 24 cores

Where it is used: inside data centres, office floor distribution, LAN backbone, in-building CCTV and automation networks.

Datwyler also cuts this group to length; Belden supplies standard reel lengths. If your specification calls for a particular CPR fire class (for example Dca or B2ca), state it in the quote request — the cable type changes with the class.

Patch cord

Fiber optic patch cord

Flexible pre-terminated assemblies for links inside the rack and between equipment. We build PROTELFiBER patch cords to order the way Telegärtner does, and because production is in Turkey the lead time is far shorter.

PROTELFiBER — 1–5 working days

  • Connector types: LC, SC, ST, FC
  • Simplex and duplex
  • Singlemode (OS2) and multimode (OM3, OM4)
  • Made to order in any length
  • Common long-length reel cable is also in stock and is wound to the length you need

IRENIS — MPO/MTP patch cords

We bring in the high-density MPO and MTP assemblies used in data centres from IRENIS to order. A minimum order quantity applies and the lead time is 3–6 weeks.

Choosing a fiber optic cable

Singlemode or multimode?
For any distance beyond 100 m, choose singlemode (OS2, G.652.D). Multimode (OM3/OM4) only makes sense over short in-building runs or when you are extending an existing multimode plant. The singlemode cable itself is not more expensive; the difference is on the active equipment side.

How many cores should I buy?
At least twice what you use today. Pulling labour costs more than the cable itself, and adding cores later means pulling new cable. Four times is a common choice on backbone routes.

Indoor or outdoor?
Outdoors, UV resistance and a moisture barrier are essential. If the cable enters the building and continues inside, there are two options: terminate at the entry and change to LSZH cable, or use universal (indoor/outdoor) cable from the start. Fire regulations usually decide the second case.

When is armoured cable needed?
On routes with rodent risk, for direct burial, and in industrial areas where crushing is a risk. Steel armour makes the cable heavier and increases the bending radius; check tight routes before you order.

What length should I order?
Add termination allowances to the route length. Because Datwyler cuts to length you do not have to buy more cable than you need; with Belden the standard reel lengths apply and the remainder stays on the project.

Which manufacturer should I choose?
For rack patch cords and fast delivery, PROTELFiBER — 1–5 working days. For field cable where length flexibility and a short lead time matter, Datwyler. For breakout distribution cable, Telegärtner made-to-order production is strong. If a specific Belden part number is in the specification, Belden. For data centre MPO/MTP, IRENIS. If you are not sure, send us the project and we will compare.

Fiber types

Fiber type Core diameter Typical distance Common use
OS2 singlemode (G.652.D) 9 µm 10 km and beyond Backbone, campus, carrier network
OM4 multimode 50 µm ~400 m at 10 Gbit Data centre, high speed
OM3 multimode 50 µm ~300 m at 10 Gbit Data centre, in-building
OM1 multimode 62.5 µm ~275 m at 1 Gbit Existing legacy plant

Attenuation, bandwidth and similar figures vary by manufacturer and production batch. For that reason we do not publish generic values on this page; we obtain the current datasheet for the product you choose from the manufacturer and send it with the quote.

Delivery and lead times

Manufacturer Lengths Typical lead time Note
PROTELFiBER Wound from stock to the length you need, or made to order 1–5 working days Our own brand. Patch cords and common reel types in stock
Datwyler Cut to the length you specify Under 3 weeks An order such as 225 m is possible; no leftover reel
Telegärtner Made-to-order configuration 4–6 weeks You design your own cable with the online configurator
Belden Standard reels: 1050, 2100, 4200 m 4–8 weeks Around 500 cable types
IRENIS MPO/MTP patch cords 3–6 weeks To order, minimum order quantity applies

Shipments leave from our Istanbul and Germany warehouses. For urgent projects ask about stock first; we usually answer the same day.

Request a fiber optic cable quote

To speed up the quote, please include:

  • Part number if you have one (Belden, Datwyler, Telegärtner or PROTELFiBER)
  • Length — total length and how many pieces
  • Fiber type and core count — if you do not know, describe the project and we will work it out
  • Indoor / outdoor, and whether armour is needed
  • Connector type if you need patch cords (LC, SC, ST, FC, MPO/MTP)
  • Fire class (CPR) if your specification states one
  • Delivery place and date

Not knowing the part number is not a problem. Describe the route and the environment and we will choose the right cable and send it with our reasoning.

E-mail: [email protected]  ·  Phone: +90 212 221 80 60  ·  WhatsApp: +90 532 265 91 99

Frequently asked questions

Can I order a short length such as 225 m?
Yes. Datwyler cable is cut to the length you specify, so you are not tied to a standard reel. With Belden the standard reel lengths of 1050, 2100 and 4200 m apply.

What is the lead time?
PROTELFiBER 1–5 working days, including stock winding and made-to-order patch cords. Datwyler under 3 weeks. Telegärtner made-to-order 4–6 weeks, Belden 4–8 weeks. IRENIS MPO/MTP patch cords 3–6 weeks. The exact time depends on the product and quantity; we state it in the quote.

Should I buy singlemode or multimode?
Singlemode (OS2) for distances beyond 100 m. Multimode is preferred only for short in-building runs or when extending an existing multimode plant.

I do not know the part number. Can I still get a quote?
Yes. Send the route length, whether it is indoor or outdoor, your estimated core count and any fire class requirement; we will recommend a suitable cable and explain why.

Can the cable be delivered with connectors fitted?
We build PROTELFiBER patch cords to order in the length and connector combination you need; LC, SC, ST and FC are available and delivery is 1–5 working days. MPO/MTP assemblies come from IRENIS to order (MOQ applies, 3–6 weeks). Field cable is normally terminated during installation.

Do you ship outside Turkey?
Yes. We ship from our Istanbul and Germany warehouses. Reach us through the quote form, by e-mail, or on WhatsApp at +90 532 265 91 99.

Consult us for more information.
Contact our experts for technical details and product selection support.