Local Area Network (Ethernet), Data Communications, Data Center Cables
Cat-5, Cat 5e +, Cat 6, Cat 6, Cat 7, Cat 7 Network Cables
Belden Network Cable Selection criteria:
Standards:
Category 5e (Cat 5e)
+ Category 5e (Cat 5e +)
Category 6 (CAT 6)
Category 6 (Cat 6a)
Category 7 (CAT 7)
Kategori 7A (Cat 7A)
Belden Network Cable Selection criteria:
Cable structure:
• Indoor use of PVC
• Halogen-free cable for indoor use only halogen-free structure
• Fire resistant cables for indoor use but a certain amount of fire resistant
• Outdoor groundwater use PA
• Extra-strong outer coating of crushing reinforced structure against external factors such as bending the outer casing
Belden Network Cable Selection criteria:
Usage areas:
• Installation Cable Network (LAN) fixed systems, the use of horizontal installation. The inner conductor is single stranded
• Patch Cable Network (LAN) mobile interconnection systems. The inner conductor is stranded.
• RGB video transmission
• Industrial data communication
U / UTP twisted pair of no shielding on. Belden UTP cable for all models.
F / UTP all over the double foil shield, drain wire there. Of Cat5e and Cat6 cables F / UTP shielded There are models.
SF / UTP foil shield on all pairs thereon zinc coated copper braid shield, has drain wire. Of Cat5e and Cat6 cable SF / UTP shielded There are models.
The / FTP Each pair of inner conductor foil comprising a display screen, but no common kablonunt pairs.
F / FTP each pair of inner conductive aluminum foil shield, all couples with foil shielded, there ripcord.
S / FTP each pair of inner conductive aluminum foil shielded, couples together all zinc plated braided copper shield, there ripcord. Belden Cat7 S / FTP is screened.
Category 7, 7A
Category 6, 6A
Category 5e, 5e +
1000 -1200 MHz up performance
Structured cabling solution copper cable, Category 7, which may go far beyond the performance of the standard Belden Cat7 shielded cable (S / FTP) as offered for sale. BELDEN the structural cabling products, has reached the end point of technology is the right choice for the future and guaranteed because the transfer to the user.
Belden Cat 7 and Cat 7A kinds of features:
1885ENH articulated , S / FTP
Cat 7, halogen, AWG 23/01
1886ENH articulated , S / FTP
Cat 7a, halogen, AWG 23/01
1888ENH articulated , S / FTP
Cat 7a, halogen, AWG 01/22
1887ENH Belden , S / FTP
Double Cat 7, halogen, AWG 23/1
74004NH Belden , S / FTP
Double Cat 7, halogen, AWG 26/7
74004P of Belden , S / FTP
Double Cat 7, halogen, AWG 23/1
74005P of Belden , S / FTP
Double Cat 7, halogen, AWG 26/7
Performance of up to 600 to 625 MHz
Structured cabling copper wire are solved, Category 6 CAT6 cable Belden can be far beyond the performance of the standard, ekransuz (UTP) and screened (F / UTP, SF / UTP) as offered for sale. BELDEN the structural cabling products, has reached the end point of technology is the right choice for the future and guaranteed because the transfer to the user.
Belden Cat 6, Cat 6A varieties and characteristics:
10GXE01 articulated , F / FTP Cat 6, halogen, AWG 01/23
10GXE02 articulated , S / FTP Cat 6, halogen, AWG 23/01
10GXE00 articulated , F / UTP
Cat 6a, halogen, AWG 01/23
Belden 10 GX Series 10 GbE cables brochure
10 Belden cabling system GX Series brochure
Articulated 7860ENH F / UTP
Cat 6, halogen, AWG 23/01
Articulated 7860ENS SF / UTP
Cat 6, flame-retardant (FRNC), AWG 01/23
Belden 7965E U/UTP
Cat 6, PVC, AWG 23/1
Articulated 7965ENH U / UTP
Cat 6, halogen, AWG 23/01
Articulated 7965P to U / UTP PA
Cat 6, PE outer sheath, AWG 23/01
Articulated to 7812 U / UTP
Cat 6, PVC, adherent per AWG 1/23
Articulated 7813LC U / UTP
Cat 6, Teflon outer jacket adherent per AWG 1/23
Articulated 2413 U / UTP
Cat 6, Teflon outer jacket, flame-retardant, AWG 01/23
Articulated 2424 U / UTP
Cat 6, halogen, AWG 23/01
2400 Series product releases Belden
Articulated 1872 U / UTP
Cat 6, PVC, adherent PR, RS-422, AWG 01/23
Articulated to 7851 U / UTP
Cat 6, PVC, adherent PR, RS-422, AWG 23/01
Belden 7989 is U / UTP
Cat 6, PVC, conjoined pair, according to the RGB video transmission, AWG 23/1
Belden Cat6 Interconnect (patch) network cable and features:
Interconnect (patch) cables must be flexible. However, despite the flexibility of the structure should be stable flex bends, otherwise the bandwidth available cable data transfer rate therefore falls. The use of high-quality patch cables Cat.6 environment is a must.
adherent patch cords twisted articulated Cat.6 500MHz to 1875GB model has been tested up to 250 MHz model 7883 normally twisted.
Articulated 1875GB U / UTP Patch Cable
Cat 6, adherent PR, RS-422, AWG 24/07
Belden 7883 U / UTP Patch Cables
Cat 6, PVC, AWG 24/1
Belden Cat6 network cables and industrial quality features (for severe ambient conditions):
Outdoor sunlight, oil, acid, which is in contact with chemicals such as gas, the Cat.6 cables to be used in environments where the risk of crushing the cable must have very different characteristics in the structure. Belden Teflon coated for harsh outdoor conditions, double PVC outer coating surface, steel manufactures armored cables Cat.6.
Articulated to 7927 U / UTP
sunlight and oil resistant
Cat 6, Industrial PVC sheath, RS-422, AWG 23/01
Articulated to 7931 U / UTP
sunlight, FEP outer coating resistant to oil and gas
Cat 6, Teflon outer jacket, RS-422, AWG 01/23
Articulated to 11,872 U / UTP
double layered PVC coating, sunlight and oil resistant
Cat 6, Industrial PVC sheath, RS-422, AWG 01/23
Articulated 121,872 to U / UTP
aluminum armor outer coating, sunlight and oil resistant
Cat 6, Industrial PVC sheath, RS-422, AWG 01/23
Articulated 1302A S / FTP Portable
special alloy copper inner conductor. Foil shield,
tinned copper drain wire. 4 pairs (pair) x AWG24
2412D Belden U / UTP
special alloy of copper inner conductor. CAT6 + class
Articulated 2425D U / UTP
Cat 6+ class 300MHz. Special alloyed copper inner conductor.
4 pairs (pair) x AWG 24
Performance up to 350 MHz
Structured cabling solution copper cable, Category 5 standards of performance far beyond the removable Articulated Cat5 cables, ekransuz (UTP) and screened (F / UTP, SF / UTP) offered as Satoshi. BELDEN the structural cabling products, has reached the end point of technology is the right choice for the future and guaranteed because the transfer to the user.
Belden Cat 5e types and features:
Belden 1583E, U/UTP
Cat 5e, AWG 24/1
Articulated 1583ENH , U / UTP Cat 5e, halogen, AWG 24/01
Articulated 1583EP to U / UTP
Cat 5e, PE outer sheath, AWG 01/24
Belden 1633E, F/UTP
Cat 5e, AWG 24/1
1633ENH articulated , F / UTP
Cat 5e, halogen, AWG 24/01
Articulated 1633P to F / UTP
Cat 5e, PE outer sheath, AWG 01/24
1633ES articulated , SF / UTP
Cat 5e, PVC sheath, AWG 24/01
1700 articulated U / UTP
Cat 5e, PVC sheath, AWG 24/01
Articulated to 7997 U / UTP
Cat 5e, gel-filled PE outer sheath, AWG 01/24
Belden 7988 is U / UTP
Cat 5e, PVC, according to the RGB video transmission, AWG 24/1
Belden Cat5 Interconnect (patch) network cable and features:
Interconnect (patch) cables must be flexible. However, despite the flexibility of the structure should be stable flex bends, otherwise the available bandwidth data transmission speed decreases due to cable
Belden 1752 to U / UTP Patch Cables
Cat 5e + PVC outer sheath, AWG 24/7
Belden 1868 to F / UTP Patch Cable
Cat 5e, PVC outer sheath, AWG 26/7
Commonly Used Belden Network (LAN) Cables
Cat5e (shielded) Cable Installation
1633E F / UTP
CAT5e shielded, guaranteed performance tested up to 100 MHz, 1633ENH halogen model 1668 A model within the combined pairs 1633,1633ENH halogen model.
1633ES SF/UTP
CAT5e shielded, guaranteed performance tested up to 100 MHz, 1633ENS halogen model 1668ENS model 1633 to couple together, 1633ENS halogen model.
1583ENH U/ UTP
CAT5e shielded, guaranteed performance tested up to 100 MHz, 1583ENH halogen model 1668 A model within the combined pairs 1633,1633ENH halogen model.
1868E F/UTP
CAT5e shielded, guaranteed performance tested up to 100 MHz, 1868 to halogen model 1668 A model 1633 to couple together, 1633ENH halogen model.
7997A U/ UTP
Cat5e ekranlı, 100 MHz’e kadar test edilmiş performans garantisi, 7997A jel dolgulu model, 1668E çift 1633E birarada olan model,1633ENH halojensiz model.
Cat6 and Cat6A (shielded) Cable Installation
7860ENH F / UTP
Cat6A screened, but 250 MHz tested to guarantee the performance, twisted wires attached to each other (bonded-pair technology), halogen model.
7860ENS SF / UTP
Cat6A screened, but 250 MHz tested to guarantee the performance, twisted wires attached to each other (bonded-pair technology), halogen model.
10GXE01 F/FTP 10 Gigabit Ethernet
Cat6A shielded, but tested up to 625 MHz performance guarantees, halogen model.
10GXE02 S/FTP 10 Gigabit Ethernet
Cat6A shielded, but tested up to 625 MHz performance guarantees, halogen model.
10GXE00 F/UTP 10 Gigabit Ethernet
Cat6A shielded, but tested up to 625 MHz performance guarantees, halogen model.
Cat7 and Cat7A (shielded) Cable Installation
1885ENH S/FTP
Cat7 screen 1000 MHz tested to guarantee the performance, halogen model 7852 A teflon-coated retardant (Flamarrest) model 1887ENH model with double 1885ENH together.
1886ENH S/FTP 1200 MHz
Cat7 shielded, tested up to 1200 MHz performance guarantees, halogen model.
1888ENH S/FTP 1200 MHz
Cat7 shielded, tested up to 1200 MHz performance guarantees, halogen model.
74004NH S/FTP 1000 MHz
Cat7 screened, tested up to 1000 MHz performance guarantees, halogen model.
74004PU S/FTP 100 MHz
Cat7 screened, tested up to 100 MHz performance guarantees, halogen model.
74005PU S/FTP 600 MHz
Cat7 screened, tested up to 600 MHz performance guarantees, halogen model.
Cat5e Patch Cable
1752 to Cat5e U / UTP Patch Cables
CAT5e only tested up to 350 MHz performance guarantees, twisted wires attached to each other (bonded-pair technology).
1868 to Cat5e F / UTP Patch Cable
CAT5e shielded, tested up to 100 MHz performance guarantees, 1868ENH halogen model.
1583ENH Cat5e U / UTP Patch Cables
CAT5e shielded, tested up to 100 MHz performance guarantees, 1583ENH halogen model.
1633 to Cat5e F / UTP Patch Cable
CAT5e shielded, tested up to 100 MHz performance guarantees, 1633 to halogen model.
7997 to Cat5e U / UTP Patch Cables
CAT5e shielded, guaranteed performance tested up to 100 MHz, 7997 to the gel-filled model.
Cat5e (U/UTP, unshielded) Cable Installation
Tested up to 200 MHz performance guarantees, 1583ENH halogen model 1583EP the PE outer covering outdoor / underground model 1667 A model 1583 dual together but 100 MHz, 1667ENH halogen model
Tested up to 200 MHz performance guarantees, 1583ENH halogen model 1583EP the PE outer covering outdoor / underground model 1667 A model 1583 dual together but 100 MHz, 1667ENH halogen model
1700E (DataTwist 350)
CAT5e only tested up to 350 MHz performance guarantees, twisted wires attached to each other (bonded-pair technology) 1700ENH halogen model, model 1702 dual together within 1700, halogen model 1702ENH
7997A (datatwist 5 Open Air)
PE outdoor cable, gel-filled Cat5e only tested up to 200 MHz performance guarantee.
Cat6 (U/UTP, unshielded) Cable Installation
It Cat6A only tested up to 250 MHz performance guarantees, 7965ENH halogen model.
It Cat6A only tested up to 300 MHz performance guarantees, 2412D halogen model.
It Cat6A only tested up to 300 MHz performance guarantees, 2425D halogen model.
Cat6A only tested up to 250 MHz performance guarantees, twisted wires attached to each other (bonded-pair technology) 7812ENH halogen model 7852 A teflon-coated retardant (Flamarrest) model
1872A (Mediatwist)
It Cat6A only tested up to 500 MHz performance guarantees, twisted wires attached to each other (bonded-pair technology), 1874 teflon coated retardant (Flamarrest) model
7851A (DataTwist 600e)
It Cat6A only tested up to 600 MHz performance guarantees, twisted wires attached to each other (bonded-pair technology) 7851NH halogen model 7852 teflon coated retardant (Flamarrest) model
IBM Type Cable
Belden 9688 IBM Type 1A
Data is not full
IBM part no: 4716748 33G2772
Two shielded pairs, 22 AWG solid copper conductors,
150 Ohm, 300 MHz
Belden 82688 IBM Type 1A
Plenum Data
IBM part no: 4716749 33G82202
Two shielded pairs, 22 AWG solid copper conductors
150 Ohm, 300 MHz
Belden 1634A IBM Type 1
Data is not full
IBM part no: 4716748
Two shielded pairs, 22 AWG solid copper conductors
150 Ohm, 16 MHz
Belden 9689 IBM Type 2A
Non Plenum Data & Telephone
IBM part no: 4716739 33G2773
Two shielded pairs, 22 AWG solid copper conductors and
the fourth audio class pair, 22 AWG solid copper conductors
150 Ohm (data), 600 Ohm (ses), 300 MHz (data)
Belden 82689 IBM Type 2A
Plenum Data & Telephone
IBM part no: 4716738 33G8221
Two shielded pairs, 22 AWG solid copper conductors and
the fourth audio class pair, 22 AWG solid copper conductors
150 Ohm (data), 600 Ohm (ses), 300 MHz (data)
Belden 1215A IBM Type 6A
Patch Panel Data
IBM part no: 4716743 33G2775
Two shielded pairs, 26 AWG solid copper conductors
150 Ohm, 300 MHz
Cat6 Patch Cable
1875GB Cat6 U / UTP Patch Cables
It Cat6A only tested up to 500 MHz performance guarantees, twisted wires attached to each other (bonded-pair technology).
7883 Cat6 U / UTP Patch Cables
It Cat6A only tested up to 250 MHz performance guarantees, twisted wires attached to each other (bonded-pair technology), RJ-45 connector compatible.
7965ENH Cat6 U / UTP Patch Cables
It Cat6A only tested up to 250 MHz performance guarantees, twisted wires attached to each other (bonded-pair technology), RJ-45 connector compatible.
2412D Cat6 U / UTP Patch Cables
It Cat6A only tested up to 300 MHz performance guarantees, twisted wires attached to each other (bonded-pair technology), RJ-45 connector compatible.
2425D Cat6 U / UTP Patch Cables
It Cat6A only tested up to 300 MHz performance guarantees, twisted wires attached to each other (bonded-pair technology), RJ-45 connector compatible.
RGB Video Cable
7989 is Cat6 U / UTP Cable RGB
It Cat6A only tested up to 250 MHz performance guarantees, twisted wires attached to each other (bonded-pair technology), 7989P plenum model.
7988 is Cat5e U / UTP Cable RGB
CAT5e only tested up to 200 MHz performance guarantees, twisted wires attached to each other (bonded-pair technology), 7988P plenum model.
RGB Video Kablosu
7989R Cat6 U/UTP RGB Kablosu
Cat6 ancak 250 MHz’e kadar test edilmiş performans garantisi, bükümlü teller birbirine yapışık (bonded-pair teknolojisi), 7989P plenum modeli.
7988R Cat5e U/UTP RGB Kablosu
Cat5e ancak 200 MHz’e kadar test edilmiş performans garantisi, bükümlü teller birbirine yapışık (bonded-pair teknolojisi), 7988P plenum modeli.
Network (LAN) Cables New Product Releases
Technical documentation, product releases:
Cable Preparation Tool Speeds Installation of Bonded-Pair Cables
New Datatwist 600e: Guaranteed Performance to 600 MHz
New Datatwist 5e+: Enhanced 5e Performance Guaranteed to 350 MHz
Belden Introduces Home Automation Cables with Verified Cat.5 Performance
NP289 Belden Belden® datatwist® 2400 Cables
The Impact of Installation Stresses On Cable Performance
Belden 625MHz established NASA and provides network performance 10 Gigabit structured cabling system
Belden’s Conjoined Twisted Pair Technology (Bonded-Pair)
Conjoined twisted pairs (Bonded-Pair) and just twisted pairs
Board performance is the performance in real-world conditions of a channel setup. Curled into real-world use and services of the coil wire pulled violently stretched between the folds and corners common conditions and / or output cables are also packed into boxes. Belden cables are unique double-adherent, they provide better performance thanks to the patented design of the installation.
Design a hotspots d aha i t
a robust design for individual conductors, twisted-pair cable and the pair of them starts with creating relationships with each other.
Ideally, such a pair of mirror image of each other, consists of two insulated conductors are perfectly balanced. A copper is used in the same boyutlardadır- -tıpatıp two conductors and each insulated conductor in the center, or concentrically located.
Ideally twisted-pair cable, excellent concentricity and eccentricity.
This center-to-center distance between copper conductors to maintain the perfect balance, or centrality should be fixed and never change, even the slightest degree! Balanced signal transmission or an ideal pair concentricity and centrality elements enables the signal to be double or leakage of radiation and deletes all the noise coming from outside the couple.
When a twisted pair of conductors separated by impedance mismatch, return loss and crosstalk problems out back. Articulated to prevent this separation and patented double-adherent to impart structural integrity (bonded pair) has developed the technology. As seen in the picture, glued-pair cable will remain the same even when the distance from the conductor to conductor-crimped.
When the twisted pair cable in a corner, but adhesions double (bonded pair) inseparable.
Performance-Based Design
Belden twisted-pair cables are designed to maintain their exceptional performance after installation. A Stress Test setup designed and implemented to show it. Cable tray of the cable, each cable to the ceiling and a series of controlled withdrawal of my eşbenzeti around and through the walls subjected to twist and curl. Then, on one end side of the work station of the cable it is formed into loosely service ring. Cables prior to testing to determine any changes in the performance and then were evaluated.
Conjoined dual-Cat5e cable Belden we compare with those of industry-leading return loss values Cat5e wire off, return loss of 12 dB value of the separate pair of cables; or we can see that compared to the pre-installation value deteriorates more than 15-fold.
Belden’s cables showed conjoined double-pekaz changes in the return loss performance. (For more information, Belden’s TB66 and No. Typical Installation of Cable Effects of Stress Performance refer to the Technical Bulletin entitled)
Performance lowers cost
Conjoined double-articulated and has done research on the installation contractor in the eyes of many experiments to document better-pair cables as well as a separate installation of the post-performance.
After the installation is complete this study have seen a clear difference between the two types and both proposed Category 6 cable, as well as field tests to verify compliance with the industry standard Category 5e was conducted.
Aslında yapışık-çift kablolarda çok daha az sorun arama ve ek iş gerektiğinden, drop başına 1.5 dakikaya (Cat 5e) ve drop başına 2.5 dakika (Cat 6) varan zaman tasarrufu tahmin edilir.
(Daha ayrıntılı bilgi için lütfen Belden Teknik Bülten TB-67’ye bakınız: Yüklenici Saha-Testi Araştırması Yapışık-Çift Kabloların Kullanımına İlişkin Maliyet Tasarrufunu Ortaya Çıkardı).