Belden industrial cables
Belden PLC/DCS Cable Cross Reference
Find the manufacturer and the network of your PLC or DCS and read off the matching Belden cable code. 22 manufacturers and 93 systems, based on Belden’s own cross reference guide.
- 22 manufacturers
- 93 systems and networks
- Siemens, ABB, Rockwell, Schneider
- Yokogawa, Emerson, Honeywell
- Common types in stock
- Cut lengths
We keep commonly used types in stock and supply cut lengths as well as full reels. We ship worldwide from our warehouses in Germany and Turkey.
Request a quote by part number Help me choose the right cable

Belden cable by PLC and DCS manufacturer
Find the manufacturer first, then the system or network. Code links open the Belden datasheet.
| System or network | Belden cable codes |
|---|---|
| ABB / Bailey | |
| Industrial IT 800xA | 9880 |
| Infinet | 9880, 9463 |
| Masterpiece 200 | 9880, 9907 |
| MICRO-DCI | 3105A |
| MICROLINK | 9860 |
| Modcell | 3105A |
| Allen-Bradley / Rockwell Automation | |
| ControlNet | 3092A, 3092F, 3093A, 123092A |
| DH, DH+, Remote I/O | 9463, 9463F, 129463, 139463, 189463, 9463DB, 3072F, 89463 |
| DH-485 | 3074F, 3106A, 9842 |
| Longline Communications | 8723, 88723 |
| DeviceNet | Belden DeviceNet cables (codes in the protocol table below) |
| Industrial Ethernet | Belden Industrial Ethernet cables (codes in the protocol table below) |
| Cutler-Hammer / Westinghouse | |
| I/Q System | 9463 |
| Echelon | |
| LonWorks | 8471, 8917, 85102 |
| Emerson Process Management | |
| DeviceNet | Belden DeviceNet cables (codes in the protocol table below) |
| Foundation Fieldbus | Belden Foundation Fieldbus cables (codes in the protocol table below) |
| Fisher / Rosemount HART | Belden HART cables (codes in the protocol table below) |
| Fisher / Rosemount Modbus | Belden Modbus cables (codes in the protocol table below) |
| DeltaV Profibus DP | Belden PROFIBUS cables (codes in the protocol table below) |
| RS-485 | Belden RS-485 cables (codes in the protocol table below) |
| Ovation / Provox Plus | 3091A, 3131A |
| GE Energy | |
| Mark VI, Mark VIe, EX2100 | Belden Industrial Ethernet cables (codes in the protocol table below) |
| GE Fanuc | |
| DeviceNet | Belden DeviceNet cables (codes in the protocol table below) |
| 90-30 / 90-70 Communications Bus | 9182 |
| PACSystems | 89182 |
| Honeywell | |
| Access 4000 | 9248 |
| IPC 620 System I/O | 9271 |
| IPC 620 Serial Interface | 9729, 9182, 89182 |
| TDC 3000 UCN & LCN | 3131A, 3094A |
| Smart Distributed System (SDS) | 3086A, 3087A |
| Invensys / Foxboro | |
| Foundation Fieldbus | Belden Foundation Fieldbus cables (codes in the protocol table below) |
| Industrial Ethernet | Belden Industrial Ethernet cables (codes in the protocol table below) |
| I/A Series Carrier Band | 8233, 3095A, 9290 |
| I/A Series Fieldbus | 9207, 89207, 3073F |
| I/A Series Node Bus | 9880, 89880 |
| Limitorque | |
| DDC-100 | 3105A |
| Matsushita | |
| FP Series C-NET, MEWNET-F, MEWNET-TR, MEWNET-W2, TRNET | 9207, 9860 |
| FP Series MEWNET-H | 9248 |
| FP Series MEWNET-W | 9207 |
| Mitsubishi Electric | |
| CC-Link | 1348A, 1349A |
| DeviceNet | Belden DeviceNet cables (codes in the protocol table below) |
| MELSECNET II (10/10H) | 1505A, 1505F, 1506A, 8241, 8241F |
| Modbus | Belden Modbus cables (codes in the protocol table below) |
| Profibus DP | 3079A, 3079E |
| Serial Communications | 8777 |
| Modicon / Schneider Electric | |
| Industrial Ethernet | Belden Industrial Ethernet cables (codes in the protocol table below) |
| Modbus | Belden Modbus cables (codes in the protocol table below) |
| Modbus II | 3092A, 3132A, 3092F, 123092A |
| Modbus Plus | YM29560, YC39000, YC39222, YQ29258 |
| Remote I/O | 3092A, 3092F, 123092A, 3132A, 3094A, 3095A |
| Omron | |
| CompoBus/D (DeviceNet) | Belden DeviceNet cables (codes in the protocol table below) |
| CompoBus/S | 9409, 9318, 3073F, 89740 |
| Controller Link | 9207, 89207, 9815, 3073F |
| Industrial Ethernet | Belden Industrial Ethernet cables (codes in the protocol table below) |
| SYSBUS-2 | 3073F |
| SYSMAC BUS | 9841, 3105A |
| Phoenix Contact | |
| DeviceNet | Belden DeviceNet cables (codes in the protocol table below) |
| Industrial Ethernet | Belden Industrial Ethernet cables (codes in the protocol table below) |
| Interbus-S | 3119A, 3120A |
| Profibus DP, FMS & PA | Belden PROFIBUS cables (codes in the protocol table below) |
| Reliance | |
| R-Net | 9259, 89259 |
| Rotork | |
| Pakscan IIE RS-485 | 3105A |
| Siemens / Moore | |
| FMC RS-485 | 3105A, 3106A, 3107A, 3108A, 3109A |
| Foundation Fieldbus | Belden Foundation Fieldbus cables (codes in the protocol table below) |
| Hiway | 9860 |
| MODULNET | 3094A, 3131A |
| Profibus DP & FMS | 3079A, 3079E |
| Profibus PA | 3076F |
| SINEC H1 | 9907, 9880 |
| SINEC H2B | 3131A, 3094A |
| SINEC L1 | 3107A |
| SINEC L2 | 3079A |
| Thicknet Ethernet | 9880, 9907 |
| Smar | |
| Foundation Fieldbus | Belden Foundation Fieldbus cables (codes in the protocol table below) |
| Industrial Ethernet | Belden Industrial Ethernet cables (codes in the protocol table below) |
| Profibus DP, FMS & PA | Belden PROFIBUS cables (codes in the protocol table below) |
| RS-485 | Belden RS-485 cables (codes in the protocol table below) |
| Square D / Schneider Electric | |
| FIP / Fieldbus | 3079A, 123079A |
| Industrial Ethernet | Belden Industrial Ethernet cables (codes in the protocol table below) |
| Model 50 RS-422 | 8760 |
| Passport I/O – I/O Net | 3105A, 123105A, 3106A, 123106A |
| PowerLogic | 9841, 9842 |
| Seriplex | 3124A, 3125A, 3126A |
| SY/Net Network Trunk | 9463, 9463F, 129463, 139463, 189463, 9463DB, 3072F, 89463 |
| SY/Net TNIM | 9272 |
| Westinghouse | |
| WDPF | 9292 |
| Yokogawa | |
| CENTUM, FA-M3, STARDOM: Foundation Fieldbus | Belden Foundation Fieldbus cables (codes in the protocol table below) |
| CENTUM, STARDOM: HART | Belden HART cables (codes in the protocol table below) |
| CENTUM, FA-M3, STARDOM: Industrial Ethernet | Belden Industrial Ethernet cables (codes in the protocol table below) |
| CENTUM, FA-M3, STARDOM: Profibus | Belden PROFIBUS cables (codes in the protocol table below) |
| CENTUM, FA-M3, STARDOM: RS-485 | Belden RS-485 cables (codes in the protocol table below) |
| CENTUM, FA-M3: DeviceNet | Belden DeviceNet cables (codes in the protocol table below) |
| FA-M3: Modbus | Belden Modbus cables (codes in the protocol table below) |
If your system is not listed, send us the manufacturer, the system name and the existing cable code if you have one. We will find the Belden equivalent.
Belden cables by protocol
Open protocols are shared by many manufacturers. For each protocol you see the codes given in the Belden guide and our page with the complete range.
| Protocol | Belden cable codes |
|---|---|
| Industrial Ethernet | 7932A, 7933A, 7923A, 7918A, 7924A, 7929A, 7930A, 7922A, 7934A, 7937A, 7928A, 11700A, 11700A2, 121700A, 121700R, 7919A, 7921A, 7935A, 7936A, 7927A, 7931A, 11872A, 121872A |
| DeviceNet | 3082A, 3082F, 3083A, 3084A, 3084F, 3085A, 7895A, 7896A, 7897A, 7900A |
| Foundation Fieldbus | 3076F, 3077F, 3078F, 1327A, 1328A, 1329A, 1330A, 1331A, 1332A, 1333A, 1334A, 1335A, 1336A |
| PROFIBUS | 3079A, 3079E, 3076F |
| RS-485 | 9841, 82841, 89841, 9842, 82842, 9843, 9844, 7200A, 7201A, 7202A, 7203A, 7206A, 3105A, 3106A, 3107A, 3108A, 3109A |
| HART | 9841, 82841, 89841, 9842, 82842, 9843, 9844, 7200A, 7201A, 7202A, 7203A, 7206A, 3105A, 3106A, 3107A, 3108A, 3109A |
| Modbus | 8777, 88777 |
How to use this table
The table follows the assignments in Belden’s PLC/DCS cable cross reference guide. Codes that are no longer on Belden’s current website have been removed.
Final selection
Where several codes are given for one system, the difference is usually the jacket, the armour or the flexibility. For the final choice follow the cable requirement in the device installation manual, or ask us.
Modbus Plus
The codes starting with YM and YC are cables Belden makes specifically for Modbus Plus. We confirm their current status when we quote.
Armoured and halogen-free versions
Many cables in the table also exist in armoured and LSZH versions. The complete range is on the page of each protocol.
Why Belden?
- Cables for almost every PLC and DCS network from one manufacturer
- A cross reference published by Belden and matched to the vendors’ systems
- PVC, LSZH, plenum and armoured versions of the same cable
- A datasheet for each code on belden.com
Why PROTEL?
- Authorised Belden distributor. Products come directly from the manufacturer.
- Stock. Commonly used types are kept in stock.
- Cut lengths. You do not have to buy a full reel.
- Selection support. Tell us your line and devices; we recommend a type and explain why.
- Worldwide supply. Shipped from our warehouses in Germany and Turkey.
Frequently asked questions
Which Belden cable is used for Siemens Profibus?
The Belden guide gives 3079A and 3079E for Profibus DP and 3076F for Profibus PA.
Which Belden cable is used for Allen-Bradley DH+ and Remote I/O?
The 9463 Blue Hose family: 9463, the flexible 9463F, the direct burial 9463DB and the armoured versions.
Which Belden cables are listed for Yokogawa CENTUM?
Belden gives separate codes for Foundation Fieldbus, HART, Profibus, RS-485, DeviceNet and industrial Ethernet. See the Yokogawa heading in the table.
The code on my existing cable is from another brand. Can you find the equivalent?
Send us the construction of the cable (pairs, conductor size, impedance, shield, jacket) or its datasheet. We will name the Belden code with the same characteristics.
Do I have to buy a full reel?
No. We supply cut lengths. The part number and the total length are enough.
Request a quote
- If you know the code: the part number, total length and delivery country are enough.
- If you do not: send your application, line length and environment; we recommend the type.
- If you have a specification or BOQ: send it and we will return the matching part numbers.
Technical documents
Product images and technical information on this page are © Belden Inc. and are used with the manufacturer’s permission. Technical values are taken from the manufacturer’s datasheets; the current datasheet is binding. Source: belden.com
Call us for more information.
Consult PROTEL experts for more details, technical information and routing assistance regarding BELDEN cables.