Belden industrial data cables
Belden Armored Data Cable
Belden data cables with factory-applied armour for runs without conduit. Find your network in the list, pick the armour type and send us the code and the length.
- Aluminium or steel interlock
- Bronze braid
- Steel wire armour
- RS-485, Fieldbus, Ethernet
- Common types in stock
- Cut lengths
We keep commonly used types in stock and supply cut lengths as well as full reels. We ship worldwide from our warehouses in Germany and Turkey.
Request a quote by part number Help me choose the right cable

Quick selection: which armour for which job
The armour type is usually set by the environment and by the project specification.
| Armour type | Typical choice when | Example Belden code |
|---|---|---|
| Aluminium interlock (AIA) | General mechanical protection without conduit | 123105A |
| Steel interlock (SIA) | Higher crush and impact resistance is needed | 133105A |
| Continuous corrugated aluminium (CCA) | A sealed metal sheath against liquids and gases is specified | 183107A |
| Bronze braid, double LSZH jacket | Marine and offshore installations | 773107T |
| Steel wire (SWA) | European-style armoured installations | 9841LS |
Tell us the network, the pair count and the environment. We will name the armoured code.
All Belden armoured data cable codes
133 armoured codes from the Belden armoured data cable range, grouped by network.
| Belden code | Construction (Belden short description) |
|---|---|
| Foundation Fieldbus (29) · unarmoured versions and all codes | |
| 3077ELS | Fieldbus, 1PR #22 Str TC, PO ins, OS, LSZH Jkt, 300V SWA |
| 123076F | Fieldbus, 1 Pr #18 Str TC, PP ins, OS, PVC Jkt, AIA Armor, PVC Jkt, ISA/SP-50 Type A, PLTC, CM |
| 123078F | Fieldbus, 1 Pr #22 Str TC, FPE Ins, OS, PVC Jkt, AIA Armor, PVC Jkt, Flexible, PLTC, ITC, CM |
| 133076F | Fieldbus, 1 Pr #18 Str TC, PP ins, OS, PVC Jkt, SIA Armor, PVC Jkt, ISA/SP-50 Type A, PLTC, CM |
| 133078F | Fieldbus, 1 Pr #22 Str TC, FPE Ins, OS, PVC Jkt, SIA Armor, PVC Jkt, Flexible, PLTC, ITC, CM |
| 153076F | Fieldbus, 1 Pr #18 Str TC, PP ins, OS, PVC Jkt, CST Armor, PVC Jkt, PLTC ISA/SP-50 Type A, PLTC |
| 323076F | Fieldbus, 1 Pr #18 Str TC, PP ins, OS, PVC Jkt, AIA Armor, CPE Jkt, ISA/SP-50 Type A, PLTC, CM |
| 753076F | Fieldbus, 1 Pr #18 Str TC, PP ins, OS, PVC Jkt, CST Armor, LSZH Jkt, PLTC ISA/SP-50 Type A, PLTC |
| 772118T | Fieldbus, 1 Pr #18 Str TC, XLPO Ins, OS, LSZH Jkt, Brnz Brd Armor, LSZH Jkt, 600V TC |
| 772119T | Fieldbus, 2 Pr #18 Str TC, XLPO Ins, IS/OS, LSZH Jkt, Brnz Brd Armor, LSZH Jkt, 600V TC-ER |
| 772120T | Fieldbus, 5 Pr #18 Str TC, XLPO Ins, IS/OS, LSZH Jkt, Brnz Brd Armor, LSZH Jkt, 600V TC-ER |
| 772121T | Fieldbus, 8 Pr #18 Str TC, XLPO Ins, IS/OS, LSZH Jkt, Brnz Brd Armor, LSZH Jkt, 600V TC-ER |
| 772122T | Fieldbus, 12 Pr #18 Str TC, XLPO Ins, IS/OS, LSZH Jkt, Brnz Brd Armor, LSZH Jkt, 600V TC-ER |
| 772127T | Fieldbus, 1 Pr #16 Str TC, XLPO Ins, OS, LSZH Jkt, Brnz Brd Armor, LSZH Jkt, 600V TC |
| 772128T | Fieldbus, 2 Pr #16 Str TC, XLPO Ins, IS/OS, LSZH Jkt, Brnz Brd Armor, LSZH Jkt, 600V TC-ER |
| 772129T | Fieldbus, 5 Pr #16 Str TC, XLPO Ins, IS/OS, LSZH Jkt, Brnz Brd Armor, LSZH Jkt, 600V TC-ER |
| 772130T | Fieldbus, 8 Pr #16 Str TC, XLPO Ins, IS/OS, LSZH Jkt, Brnz Brd Armor, LSZH Jkt, 600V TC-ER |
| 773076T | Fieldbus, 1 Pr #18 Str TC, PP ins, OS, LSZH Jkt, Brnz Brd Armor, LSZH Jkt, CMG ISA/SP-50 Type A, PLTC, ITC, CMG |
| 972008Z | Fieldbus, 1 Pr #18 Str TC, XLPO Ins, OS, LSZH-TS Jkt, Brnz Brd Armor, LSZH-TS Jkt, 600V TC |
| 972118Z | Fieldbus, 1 Pr #18 Str TC, XLPO Ins, OS, LSZH-TS Jkt, Brnz Brd Armor, LSZH-TS Jkt, 600V TC |
| 972119Z | Fieldbus, 2 Pr #18 Str TC, XLPO Ins, IS/OS, LSZH-TS Jkt, Brnz Brd Armor, LSZH-TS Jkt, 600V TC-ER |
| 972120Z | Fieldbus, 5 Pr #18 Str TC, XLPO Ins, IS/OS, LSZH-TS Jkt, Brnz Brd Armor, LSZH-TS Jkt, 600V TC-ER |
| 972121Z | Fieldbus, 8 Pr #18 Str TC, XLPO Ins, IS/OS, LSZH-TS Jkt, Brnz Brd Armor, LSZH-TS Jkt, 600V TC-ER |
| 972122Z | Fieldbus, 12 Pr #18 Str TC, XLPO Ins, IS/OS, LSZH-TS Jkt, Brnz Brd Armor, LSZH-TS Jkt, 600V TC-ER |
| 972127Z | Fieldbus, 1 Pr #16 Str TC, XLPO Ins, OS, LSZH-TS Jkt, Brnz Brd Armor, LSZH-TS Jkt, 600V TC-ER |
| 972128Z | Fieldbus, 2 Pr #16 Str TC, XLPO Ins, IS/OS, LSZH-TS Jkt, Brnz Brd Armor, LSZH-TS Jkt, 600V TC-ER |
| 972129Z | Fieldbus, 5 Pr #16 Str TC, XLPO Ins, IS/OS, LSZH-TS Jkt, Brnz Brd Armor, LSZH-TS Jkt, 600V TC-ER |
| 972130Z | Fieldbus, 8 Pr #16 Str TC, XLPO Ins, IS/OS, LSZH-TS Jkt, Brnz Brd Armor, LSZH-TS Jkt, 600V TC-ER |
| 973076Z | Fieldbus, 1 Pr #18 Str TC, PP Ins, OS, LSZH-TS Jkt, Brnz Brd Armor, LSZH-TS Jkt, CMG ISA/SP-50 Type A, PLTC, ITC, CMG |
| RS-485 (39) · unarmoured versions and all codes | |
| 3107ELS | RS-485, 2PR #22 Str TC, PO ins, F/B, LSZH Jkt, SWA |
| 3107LWS | RS-485, 2PR #22 Str TC, PO ins, F/B, LSZH Jkt, SWA, Cca |
| 9841LS | RS 485, 1PR #24 Str TC, PO ins, F/B, LSZH Jkt, 300V SWA |
| 9842LS | RS-485, 2 Pr #24 Str TC, PO ins, F/B, LSZH Jkt, 300V, SWA, Eca |
| 9843LS | RS-485, 3PR #24 Str TC, PO ins, F/B, LSZH Jkt, 300V, SWA |
| 9844LS | RS-485, 4PR #24 Str TC, PO ins, F/B, LSZH Jkt, 300V, SWA |
| 123105A | RS-485, 1 Pr, 22AWG, Str TC, PE Ins, OS+TC Brd, PVC Jkt, AIA, PVC Jkt, CM, PLTC, Sun Res |
| 123106A | RS-485, 1 Pr, 22AWG, Str TC, PE Ins, with OS, 1C 22AWG Str, PVC Ins, OA TC Brd, PVC Jkt, AIA, PVC Jkt, CM, PLTC, Sun Res |
| 123107A | RS485, 2 Pr #22 Str TC, PE Ins, OS+TC Brd, PVC Jkt, AIA Armor, PVC Jkt, CM, PLTC |
| 123108A | RS485, 3 Pr #22 Str TC, PE Ins, OS+TC Brd, PVC Jkt, AIA Armor, PVC Jkt, CMG, PLTC |
| 123109A | RS485, 4 Pr #22 Str TC, PE Ins, OS+TC Brd, PVC Jkt, AIA Armor, PVC Jkt, CM, PLTC |
| 129841 | RS485, 1 Pr #24 Str TC, PE Ins, OS+TC Brd, PVC Jkt, AIA Armor, PVC Jkt, CM |
| 129842 | RS485, 2 Pr #24 Str TC, PE Ins, OS+TC Brd, PVC Jkt, AIA Armor, PVC Jkt, CM |
| 133105A | RS-485, 1 Pr, 22AWG, Str TC, PE Ins, OS+TC Brd, PVC Jkt, SIA, PVC Jkt, CM, PLTC, Sun Res |
| 133106A | RS-485, 1 Pr, 22AWG, Str TC, PE Ins, with OS, 1C 22AWG Str, PVC Ins, OA TC Brd, PVC Jkt, SIA, PVC Jkt, CM, PLTC, Sun Res |
| 133107A | RS485, 2 Pr #22 Str TC, PE Ins, OS+TC Brd, PVC Jkt, SIA Armor, PVC Jkt, CM, PLTC |
| 133108A | RS485, 3 Pr #22 Str TC, PE Ins, OS+TC Brd, PVC Jkt, SIA Armor, PVC Jkt, CM, PLTC |
| 133109A | RS485, 4 Pr #22 Str TC, PE Ins, OS+TC Brd, PVC Jkt, SIA Armor, PVC Jkt, CM, PLTC |
| 139843 | RS485, 3 Pr #24 Str TC, PE Ins, OS+TC Brd, PVC Jkt, SIA Armor, PVC Jkt, CM |
| 139844 | RS485, 4 Pr #24 Str TC, PE Ins, OS+TC Brd, PVC Jkt, SIA Armor, PVC Jkt, CM |
| 153105A | RS-485, 1 Pr, 22AWG, Str TC, PE Ins, OS+TC Brd, PVC Jkt, CST, PVC Jkt, CMG, PLTC, Sun Res |
| 159842 | RS485, 2 Pr #24 Str TC, PE Ins, OS+TC Brd, PVC Jkt, CST Armor, PVC Jkt, CM |
| 183107A | RS485, 2 Pr #22 Str TC, PE Ins, OS+TC Brd, PVC Jkt, CCA Armor, PVC Jkt, PLTC |
| 189841 | RS485, 1 Pr #24 Str TC, PE Ins, OS+TC Brd, PVC Jkt, CCA Armor, PVC Jkt, CM |
| 323106A | RS-485, 1 Pr, 22AWG, Str TC, PE Ins, with OS, 1C 22AWG Str, PVC Ins, OA TC Brd, PVC Jkt, AIA, CPE Jkt, CM, PLTC, Sun Res |
| 333109A | RS485, 4 Pr #22 Str TC, PE Ins, OS+TC Brd, PVC Jkt, SIA Armor, CPE Jkt, CM, PLTC |
| 533105A | RS-485, 1 Pr, 22AWG, Str TC, PE Ins, OS+TC Brd, PVC Jkt, SIA, HDPE Jkt |
| 533106A | RS-485, 1 Pr, 22AWG, Str TC, PE Ins, with OS, 1C 22AWG Str, PVC Ins, OA TC Brd, PVC Jkt, SIA, HDPE Jkt |
| 533107A | RS485, 2 Pr #22 Str TC, PE Ins, OS+TC Brd, PVC Jkt, SIA Armor, HDPE Jkt |
| 539841 | RS485, 1 Pr #24 Str TC, PE Ins, OS+TC Brd, PVC Jkt, SIA Armor, PE Jkt |
| 723107A | RS485, 2 Pr #22 Str TC, PE Ins, OS+TC Brd, PVC Jkt, AIA Armor, LSZH Jkt |
| 773105T | RS-485, 1 Pr, 22AWG, Str TC, PE Ins, OS+TC Brd, LSZH Jkt, BBA, LSZH Jkt, CMG, PLTC, Sun Res |
| 773107T | RS485, 2 Pr #22 Str TC, PE Ins, OS+TC Brd, LSZH Jkt, Brnz Brd Armor, LSZH Jkt, CMG |
| 773108T | RS485, 3 Pr #22 Str TC, PE Ins, OS+TC Brd, LSZH Jkt, Brnz Brd Armor, LSZH Jkt, CMG, PLTC |
| 773109T | RS485, 4 Pr #22 Str TC, PE Ins, OS+TC Brd, LSZH Jkt, Brnz Brd Armor, LSZH Jkt, CMG, PLTC |
| 973105Z | RS-485, 1 Pr, 22AWG, Str TC, PE Ins, OS+TC Brd, LSZH-TS Jkt, BBA, LSZH-TS Jkt, CMG, PLTC, Sun Res |
| 973107Z | RS485, 2 Pr #22 Str TC, PE Ins, OS+TC Brd, LSZH-TS Jkt, Brnz Brd Armor, LSZH-TS Jkt, CMG |
| 973108Z | RS485, 3 Pr #22 Str TC, PE Ins, OS+TC Brd, LSZH-TS Jkt, Brnz Brd Armor, LSZH-TS Jkt, CMG, PLTC |
| 973109Z | RS485, 4 Pr #22 Str TC, PE Ins, OS+TC Brd, LSZH-TS Jkt, Brnz Brd Armor, LSZH-TS Jkt, CMG, PLTC |
| PROFIBUS (11) · unarmoured versions and all codes | |
| 3076ELS | Profibus PA, 1PR #18 Str TC, PO ins, OS, LSZH Jkt, 300V SWA |
| 70101LS | Profibus DP, 1PR #22 Sol BC, PO ins, F/B, LSZH/SWA/LSZH Jkt, 300 V |
| 123079A | Profibus, 1 Pr #22 Sol BC, PE Ins, OS+TC Brd, PVC jkt, AIA, PVC Jkt, PLTC CM Profibus DP |
| 123079E | Profibus, 1 Pr #22 Str BC, PE Ins, OS+TC Brd, PVC jkt, AIA, PVC Jkt, PLTC CM Profibus DP |
| 133079A | Profibus, 1 Pr #22 Sol BC, PE Ins, OS+TC Brd, PVC jkt, SIA, PVC Jkt, PLTC CM Profibus DP |
| 133079E | Profibus, 1 Pr #22 Str BC, PE Ins, OS+TC Brd, PVC jkt, SIA, PVC Jkt, PLTC CM Profibus DP |
| 153079A | Profibus, 1 Pr #22 Str BC, PE Ins, OS+TC Brd, PVC jkt, CST, PVC Jkt, PLTC CM Profibus DP |
| 183079A | Profibus, 1 Pr #22 Sol BC, PE Ins, OS+TC Brd, PVC jkt, CCA, PVC Jkt, PLTC CMG Profibus DP |
| 733079A | Profibus, 1 Pr #22 Sol BC, PE Ins, OS+TC Brd, PVC jkt, SIA, LSZH-TP Jkt, PLTC Profibus DP |
| 773079T | Profibus, 1 Pr #22 Sol BC, PE Ins, OS+TC Brd, LSZH-TP jkt, BBA, LSZH-TP Jkt, PLTC-ST1 CMG-ST1 Profibus DP |
| 973079Z | Profibus, 1 Pr #22 Sol BC, PE Ins, OS+TC Brd, LSZH-TS jkt, BBA, LSZH-TS Jkt, PLTC-ST1 CMG-ST1 Profibus DP |
| DeviceNet (21) · unarmoured versions and all codes | |
| 123082A | DeviceBus®, 2 Pr #15+18 Str TC, PVC+FPE Ins, IS+OA TC Brd, PVC Jkt, AIA Armor, PVC Jkt, CM PLTC |
| 123082F | DeviceBus®, 2 Pr #15+18 Str TC, PVC+FPE Ins, IS+OA TC Brd, PVC Jkt, AIA Armor, PVC Jkt, Flexible, CMG PLTC |
| 123083A | DeviceBus®, 2 Pr #15+18 Str TC, PVC+FPE Ins, IS+OA TC Brd, CPE Jkt, AIA Armor, PVC Jkt, CMG PLTC |
| 123084A | DeviceBus®, 2 Pr #22+24 Str TC, PVC+FPE Ins, IS+OA TC Brd, PVC Jkt, AIA Armor, PVC Jkt, CM, CL2 |
| 123084F | DeviceBus®, 2 Pr #22+24 Str TC, PVC+FPE Ins, IS+OA TC Brd, PVC Jkt, AIA Armor, PVC Jkt, Flexible, CMG, CL2 |
| 123085A | DeviceBus®, 2 Pr #22+24 Str TC, PVC+FPE Ins, IS+OA TC Brd, PVC Jkt, AIA Armor, CPE Jkt, CM, CL2 |
| 123086A | DeviceBus® for Honeywell SDS, 2 Pr #16+20 Str TC, PVC+FPE Ins, IS, PVC Jkt, AIA, PVC Jkt, CL2 |
| 127895A | DeviceBus®, 2 Pr #18+20 Str TC, PVC+FPE Ins, IS+OA TC Brd, PVC Jkt, AIA Armor, PVC Jkt, PLTC |
| 127896A | DeviceBus®, 2 Pr #16+18 Str TC, PVC-NYL+PP Ins, IS+OA TC Brd, PVC Jkt, AIA Armor, PVC Jkt, CMG CSA HL |
| 127897A | DeviceBus®, 2 Pr #15+18 Str TC, PVC-NYL + FEP Ins, IS+OA TC Brd, PVC Jkt, AIA, PVC Jkt, 600V |
| 133082A | DeviceBus®, 2 Pr #15+18 Str TC, PVC+FPE Ins, IS+OA TC Brd, PVC Jkt, SIA Armor, PVC Jkt, CM PLTC |
| 133082F | DeviceBus®, 2 Pr #15+18 Str TC, PVC+FPE Ins, IS+OA TC Brd, PVC Jkt, sIA Armor, PVC Jkt, Flexible, CM PLTC |
| 133083A | DeviceBus®, 2 Pr #15+18 Str TC, PVC+FPE Ins, IS+OA TC Brd, CPE Jkt, SIA Armor, PVC Jkt, CM PLTC |
| 133084A | DeviceBus®, 2 Pr #22+24 Str TC, PVC+FPE Ins, IS+OA TC Brd, PVC Jkt, SIA Armor, PVC Jkt, CM, CL2 |
| 137897A | DeviceBus®, 2 Pr #15+18 Str TC, PVC-NYL + FEP Ins, IS+OA TC Brd, PVC Jkt, SIA, PVC Jkt, 600V |
| 183082A | DeviceBus®, 2 Pr #15+18 Str TC, PVC+FPE Ins, IS+OA TC Brd, PVC Jkt, CCA Armor, PVC Jkt, CMG PLTC |
| 187897A | DeviceBus®, 2 Pr #15+18 Str TC, PVC-NYL + FEP Ins, IS+OA TC Brd, PVC Jkt, CCA Armor, PVC Jkt, CSA HL |
| 623082A | DeviceBus®, 2 Pr #15+18 Str TC, PVC+FPE Ins, IS+OA TC Brd, PVC Jkt, AIA Armor, PVC Jkt, CM PLTC |
| 723082A | DeviceBus®, 2 Pr #15+18 Str TC, PVC+FPE Ins, IS+OA TC Brd, PVC Jkt, AIA Armor, LSZH Jkt |
| 777896T | DeviceBus®, 2 Pr #16+18 Str TC, XLPe+PP Ins, IS+OA TC Brd, LSZH Jkt, BBA, LSZH Jkt, 600V TC-ER-ST1 |
| 977896Z | DeviceBus®, 2 Pr #16+18 Str TC, XLPO+PP Ins, IS+OA TC Brd, LSZH-TS Jkt, Brnz Brd Armor, LSZH-TS Jkt, 600V TC-ER-LS |
| Industrial Ethernet (19) · unarmoured versions and all codes | |
| 121700A | DataTuff® Cat 5e, 4 Bonded-Pr #24 Sol BC, PO Ins, PVC Jkt, AIA Armor, PVC Jkt, CMG CM |
| 121700R | DataTuff® 5e, 4 Bonded-Pr #24 Sol BC, PO Ins, PVC Jkt, AIA Armor, PVC Jkt, CMG CM -40C |
| 121702A | CAT5e+ Horizontal Bonded-Pair, 2x4pr, UTP, PVC Jkt, CMR, Siamese |
| 121872A | DataTuff® Cat 6, 4 Bonded-Pr #23 Sol BC, PO Ins, PVC Jkt, AIA Armor, PVC Jkt, CMG CM, -40C |
| 127903A | DataTuff® 5e, 4Pr #22 Sol BC, PO Ins, OS, PVC Jkt, AIA Armor, PVC Jkt, PLTC CMG CM, -40C |
| 127918A | DataTuff® 5e, 4 Pr #24 Sol BC, PO Ins, PVC Jkt, AIA Armor, PVC Jkt |
| 127919A | DataTuff® 5e, 4 Pr #24 Sol BC, PO Ins, OS, PVC Jkt, AIA Armor, PVC Jkt, CM CSA CMG HL -40C |
| 127921A | DataTuff® Cat 5e, 4 Bonded-Pr #24 Sol BC, PO Ins, OS+TC Brd, PVC Jkt, AIA Armor, PVC Jkt |
| 127922A | DataTuff® 5e, 4 Bonded-Pr #22 Sol BC, PO Ins, PVC Jkt, AIA Armor, PVC Jkt |
| 127929A | DataTuff® 5e, 4 Bonded-Pr #24 Sol BC, PO Ins, OS, PVC Jkt, AIA Armor, PVC Jkt, CMG CM -40C |
| 127931A | DataTuff® 6, 4 Pr #23 Sol BC, FEP Ins, FEP Jkt, AIA Armor, PVC Jkt |
| 127933A | DataTuff® 5e, 2 Bonded-Pr #24 Sol BC, PO Ins, OS, PVC Jkt, AIA Armor, PVC Jkt |
| 127936A | DataTuff® 5e, 4 Bonded-Pr #24 Sol BC, PO Ins, OS, PVC Jkt, AIA Armor, LSZH Jkt, CMG CM |
| 127937A | DataTuff® 5e, 4 Bonded-Pr #24 Sol BC, PO Ins, OS, PO Jkt, Foil Shld, PO Jkt, AIA Armor, PVC Jkt, OSP BURIAL |
| 127939A | DataTuff® 5e, 4 Bonded-Pr #24 Str BC, PO Ins, OS, PVC Jkt, AIA Armor, PVC Jkt |
| 127940A | DataTuff® 6, 4 Bonded-Pr #23 Sol BC, PO Ins, PVC Jkt, AIA Armor, Blk PVC Jkt, 300V CM CSA CMG HL SUN RES -40C |
| 127953A | DataTuff® Cat 6, (4 pr) 23 AWG Solid BC, PP/PVC/Alum Armor/PVC, EtherNet/IP, Foil Shld, CMG CM, 600V AWM |
| 127958A | DataTuff® 5e, 4 Bonded-Pr #23 Sol BC, PO Ins, OS, PVC Jkt, AIA Armor, PVC Jkt |
| 777940T | MarineTuff® 6, 4 Pr #23 Sol BC, PO Ins, LSZH Jkt, Brnz Brd Armor, LSZH Jkts, CMG-LS, ABS |
| Blue Hose and twinax (11) · unarmoured versions and all codes | |
| 9182LS | Twinax , 1PR #22 Str TC, PO ins, OS, LSZH Jkt, 300V, SWA |
| 9463LS | Blue Hose, 1PR #20 Str TC, PO ins, F/B, LSZH Jkt,SWA |
| 123072F | Blue Hose®, 1 Pr #18 Str TC, PP Ins, OS+TC Brd, PVC Jkt, AIA Armor, PVC Jkt, PLTC |
| 129463 | Blue Hose®, 1 Pr #20 Str TC, PE Ins Blu, Clr, Foil+TC Braid Shld, PVC Jkt, AIA Armor, PVC Jkt, CM |
| 129463D | Blue Hose®, 1 Pr #20 Str TC, PE Ins Blu, Clr, Foil+TC Brd, PE Inner Jkt, AIA Armor, PVC Jkt |
| 139463 | Blue Hose®, 1 Pr #20 Str TC, PE Ins Blu, Clr, Foil+TC Braid Shld, PVC Jkt, SIA Armor, PVC Jkt, CM |
| 189463 | Blue Hose®, 1 Pr #20 Str TC, PE Ins Blu, Clr, Foil+TC Braid Shld, PVC Jkt, CCA Armor, PVC Jkt, PLTC |
| 629463 | Blue Hose®, 1 Pr #20 Str TC, PE Ins Blu, Clr, Foil+TC Brd, PVC Jkt, AIA Armor, PVC Jkt, OIL RES II |
| 639463 | Blue Hose®, 1 Pr #20 Str TC, PE Ins Blu, Clr, Foil+TC Brd, PVC Jkt, SIA Armor, PVC Jkt, OIL RES II |
| 729463 | Blue Hose®, 1 Pr #20 Str TC, PE Ins Blu, Clr, Foil+TC Brd, PVC Jkt, AIA Armor, LSZH Jkt |
| 973072Z | Blue Hose®, 1 Pr #18 Str TC, PP Ins, OS+TC Brd, LSZH-TS Jkt, BBA, LSZH-TS Jkt, 600V TC-ER-LS |
| ControlNet (1) · unarmoured versions and all codes | |
| 123092A | ControlBus™, Coax RG6, #18 Sol BCCS, PO Ins, QUAD AL Shld, PVC Jkt, AIA Armor, PVC Jkt, CM |
| Other armoured data cables (2) | |
| 9502LS | RS-232, 2PR #24 Str TC, PO ins, OS, LSZH Jkt, SWA, 300 V |
| 733084A | DeviceNet™, (1 pr) 22 AWG Str TC, PVC Ins, (1 pr) 24 AWG Str TC, FPE Ins, IS+O/A TC Braid Shld, PVC Jkt, SIA, LSZH-TP Jkt, CL2, CMG |
Constructions are given in Belden catalogue shorthand: Pr = pair, C = conductor, Str = stranded, Sol = solid, TC = tinned copper, BC = bare copper, OS = overall shield, IS = individual shield, Brd = braid, Ins = insulation, Jkt = jacket.
Armour abbreviations: AIA = aluminium interlock armour, SIA = steel interlock armour, CCA = continuous corrugated aluminium armour, CST = corrugated steel tape, Brnz Brd / BBA = bronze braid armour, SWA = steel wire armour.
Belden also lists the unarmoured base cables in this category. You will find them on the page of each network.
Why choose an armoured data cable
Armour protects the cable against crushing, impact and rodents and lets it be laid in a tray or along a structure without conduit. The data cable inside is the same construction as the unarmoured type, so the network performance does not change.
Interlock or continuous armour?
Interlock armour is a flexible, spiral-wound metal strip. Continuous corrugated armour is a closed metal tube, chosen where liquids or gases must be kept out.
When is bronze braid used?
Bronze braid armour with LSZH jackets is the construction Belden offers for marine and offshore use.
Do I still need a shield?
Yes. The armour is mechanical protection. The foil and braid shield of the data cable underneath remains the electrical shield.
Why Belden?
- Armour applied at the factory over standard Belden data cables
- Aluminium interlock, steel interlock, continuous aluminium, bronze braid and steel wire options
- Armoured versions across RS-485, Foundation Fieldbus, PROFIBUS, DeviceNet and Ethernet
- No conduit needed, which saves material and labour
- A datasheet for each code on belden.com
Why PROTEL?
- Authorised Belden distributor. Products come directly from the manufacturer.
- Stock. Commonly used types are kept in stock.
- Cut lengths. You do not have to buy a full reel.
- Selection support. Tell us your line and devices; we recommend a type and explain why.
- Worldwide supply. Shipped from our warehouses in Germany and Turkey.
Frequently asked questions
How do I read a Belden armoured cable code?
In most cases a two-digit prefix is added to the base code: 123105A and 133105A are the aluminium and steel interlock versions of 3105A. If you know the base cable, send it to us with the armour you need.
Is there an armoured RS-485 cable?
Yes. For example 123105A, 133105A and the bronze-armoured 773105T; the full list is in the RS-485 group above.
Is there an armoured industrial Ethernet cable?
Yes. Belden lists aluminium-armoured DataTuff types such as 121700A and 121872A.
Do I have to buy a full reel?
No. We supply cut lengths. The part number and the total length are enough.
Request a quote
- If you know the code: the part number, total length and delivery country are enough.
- If you do not: send your application, line length and environment; we recommend the type.
- If you have a specification or BOQ: send it and we will return the matching part numbers.
Product images and technical information on this page are © Belden Inc. and are used with the manufacturer’s permission. Technical values are taken from the manufacturer’s datasheets; the current datasheet is binding. Source: belden.com
Call us for more information.
Consult PROTEL experts for more details, technical information and routing assistance regarding BELDEN cables.