Belden · Industrial communication cables

Belden Foundation Fieldbus Cable

Belden cables for Foundation Fieldbus and PROFIBUS PA networks. From flexible single-pair cables to 50-pair trunk cables, in PVC, rugged XLPO/TPE, halogen-free, 600 V tray-rated and armoured versions. If you know the part number, request a quote directly. If not, describe your line and we will help you choose.

  • 3076F · 3077F · 1327A
  • 1 to 50 pairs
  • 16, 18 and 22 AWG
  • Common types in stock
  • Cut lengths
PROTEL is an authorised Belden distributor

We keep commonly used types in stock and supply cut lengths as well as full reels. We ship worldwide from our warehouses in Germany and Turkey.

Request a quote by part number Help me choose the right cable

Belden Foundation Fieldbus cable

Most used Belden Foundation Fieldbus cables

Foundation Fieldbus is the process automation network that both powers and communicates with field devices over a single pair. The five most requested types are listed below; all part numbers follow in the next section.

Part number Construction Jacket and rating Choose it when Document Quote
Belden 3076F 1 pair, 18 AWG stranded (Type A) PVC · flexible · sunlight and oil resistant · −40 to +105 °C Single-device spurs and trunks in the field 3076F datasheet Request a quote
Belden 3077F 1 pair, 22 AWG stranded (Type B) PVC · flexible · UL PLTC, ITC · −30 to +105 °C Short runs that need a slimmer cable 3077F datasheet Request a quote
Belden 1334A 1 pair, 18 AWG stranded PVC · foil + braid shield · UL CMG · −40 to +105 °C Single-pair lines in noisy environments 1334A datasheet Request a quote
Belden 1327A 2 pairs, 18 AWG stranded PVC · individually and overall shielded · UL CMG Carrying several segments in one cable 1327A datasheet Request a quote
Belden 1337A 1 pair + 1 conductor, 18 AWG PVC · 600 V tray cable (TC-ER) Lines laid in the same tray as power cables 1337A datasheet Request a quote

All Belden Foundation Fieldbus cable part numbers

The tables below list Belden’s current Foundation Fieldbus cables by pair count and construction. Find the code in your specification and write to us; we quote every part number on the list.

Flexible single-pair Foundation Fieldbus cables

Type Standard Aluminium armoured Steel armoured Continuous armour
18 AWG · Type A · 300 V PLTC-ER / ITC-ER 3076F 123076F 133076F 183076F
22 AWG · Type B · 300 V PLTC / ITC 3077F — — —
22 AWG · high speed 3078F 123078F 133078F —

18 AWG multi-pair Foundation Fieldbus cables

Pairs PVC · UL CMG XLPO/TPE · UL CMG PVC · 600 V tray XLPO/TPE · 600 V tray Halogen-free · 600 V tray Halogen-free (S series)
1 1334A 2100A 1337A 2118A 2118T · 2118Z S3076NH
2 1327A 2101A 1338A 2119A 2119T · 2119Z S1327NH
5 1328A 2102A 1339A 2120A 2120T · 2120Z S1328NH
8 1329A 2103A 1340A 2121A 2121T · 2121Z S1329NH
12 1330A 2104A — 2122A 2122T · 2122Z S1330NH
16 1331A 2105A — 2123A — S1331NH
20 1332A 2106A — 2124A — S1332NH
24 1333A 2107A — 2125A — S1333NH
50 1359A 2108A — 2126A — —

16 AWG multi-pair Foundation Fieldbus cables

Pairs PVC · UL CMG XLPO/TPE · UL CMG XLPO/TPE · 600 V tray Halogen-free · 600 V tray
1 1360A 2109A 2127A 2127T · 2127Z
2 1361A 2110A 2128A 2128T · 2128Z
5 1362A 2111A 2129A 2129T · 2129Z
8 1363A 2112A 2130A 2130T · 2130Z
12 1364A 2113A 2131A 2131T · 2131Z
16 1365A 2114A 2132A —
20 1366A 2115A 2133A —
24 1367A 2116A 2134A —
36 — 2117A 2135A —

Other fieldbus cables

Part number Construction Feature
1335A 2 conductors, 16 AWG Foil + braid shield · PVC · UL CM
1336A 2 conductors, 14 AWG Foil + braid shield · PVC · UL PLTC
SI1341A · SI1342A · SI1343A · SI1344A SI series Belden Fieldbus datasheets
50097TPE · 50098TPE 2 conductors, 1.5 mm² and 2.5 mm² flat cable AS-Interface bus · TPE jacket

PVC or XLPO/TPE?

The 13xx series are standard industrial cables with a PVC jacket. The 21xx series has cross-linked polyolefin insulation and a TPE jacket, made for harsher field conditions.

600 V tray-rated Foundation Fieldbus cables

TC and TC-ER rated types are used where the communication cable shares a tray with power cables. Choose codes ending in T or Z where a halogen-free jacket is required.

Foundation Fieldbus cable for PROFIBUS PA

18 AWG Type A Foundation Fieldbus cables are also used on PROFIBUS PA lines. For single-pair PA and PROFIBUS DP cables, see our Belden PROFIBUS cable page.

Armoured versions of Belden Foundation Fieldbus cables

Many of the cables on this page are also available with factory-applied armour. Armour protects the cable against crushing and impact and allows installation without conduit. Each armoured code is shown with its unarmoured base code. The list for all networks is on Belden Armored Data Cable.

Armoured code Armour type Unarmoured base code
3077ELS Steel wire (SWA) 3077E (base code)
123076F Aluminium interlock (AIA) 3076F
123078F Aluminium interlock (AIA) 3078F
133076F Steel interlock (SIA) 3076F
133078F Steel interlock (SIA) 3078F
153076F Corrugated steel tape (CST) 3076F
323076F Aluminium interlock (AIA) 3076F
753076F Corrugated steel tape (CST) 3076F
772118T Bronze braid 2118T
772119T Bronze braid 2119T
772120T Bronze braid 2120T
772121T Bronze braid 2121T
772122T Bronze braid 2122T
772127T Bronze braid 2127T
772128T Bronze braid 2128T
772129T Bronze braid 2129T
772130T Bronze braid 2130T
773076T Bronze braid 3076T (base code)
972008Z Bronze braid 2008Z (base code)
972118Z Bronze braid 2118Z
972119Z Bronze braid 2119Z
972120Z Bronze braid 2120Z
972121Z Bronze braid 2121Z
972122Z Bronze braid 2122Z
972127Z Bronze braid 2127Z
972128Z Bronze braid 2128Z
972129Z Bronze braid 2129Z
972130Z Bronze braid 2130Z
973076Z Bronze braid 3076Z (base code)

Why Belden?

  • From one pair to 50 pairs. Every cable from spur to trunk from one manufacturer.
  • Built for harsh environments. Made to withstand temperature extremes, humidity, dust and oil; used outdoors.
  • Many shield, armour and rating options. Individually shielded pairs, 600 V tray-rated, halogen-free and armoured types.
  • A datasheet for every code. Current manufacturer documents ready for your approval and tender files.

Why PROTEL?

  • Authorised Belden distributor. Products come directly from the manufacturer.
  • Stock. Commonly used types are kept in stock.
  • Cut lengths. You do not have to buy a full reel.
  • Selection support. Tell us your line and devices; we recommend a type and explain why.
  • Worldwide supply. Shipped from our warehouses in Germany and Turkey.

Frequently asked questions about Foundation Fieldbus cable

What is Foundation Fieldbus cable?

Foundation Fieldbus is the digital field network used in process automation. Its cable is a shielded twisted pair that carries both data and power to field devices.

What is the difference between Type A and Type B Foundation Fieldbus cable?

Type A is 18 AWG and is the standard cable that allows the longest distance. Type B is 22 AWG; it is slimmer and used on shorter lines.

When is multi-pair Foundation Fieldbus cable used?

When several segments run from a junction box to the control room. As each pair is individually shielded, segments do not affect each other.

Can Foundation Fieldbus cable be used for PROFIBUS PA?

Yes. 18 AWG Type A Foundation Fieldbus cables are also suitable for PROFIBUS PA lines.

Do I have to buy a full reel?

No. We supply cut lengths. The part number and the total length are enough.

Request a quote

  • If you know the code: the part number, total length and delivery country are enough.
  • If you do not: send your application, line length and environment; we recommend the type.
  • If you have a specification or BOQ: send it and we will return the matching part numbers.

Request a quote Ask on WhatsApp

Technical documents

Product images and technical information on this page are © Belden Inc. and are used with the manufacturer’s permission. Technical values are taken from the manufacturer’s datasheets; the current datasheet is binding. Source: belden.com

Call us for more information.
Consult PROTEL experts for more details, technical information and routing assistance regarding BELDEN cables.