Belden · Industrial communication cables
Belden Foundation Fieldbus Cable
Belden cables for Foundation Fieldbus and PROFIBUS PA networks. From flexible single-pair cables to 50-pair trunk cables, in PVC, rugged XLPO/TPE, halogen-free, 600 V tray-rated and armoured versions. If you know the part number, request a quote directly. If not, describe your line and we will help you choose.
- 3076F · 3077F · 1327A
- 1 to 50 pairs
- 16, 18 and 22 AWG
- Common types in stock
- Cut lengths
We keep commonly used types in stock and supply cut lengths as well as full reels. We ship worldwide from our warehouses in Germany and Turkey.
Request a quote by part number Help me choose the right cable

Most used Belden Foundation Fieldbus cables
Foundation Fieldbus is the process automation network that both powers and communicates with field devices over a single pair. The five most requested types are listed below; all part numbers follow in the next section.
| Part number | Construction | Jacket and rating | Choose it when | Document | Quote |
|---|---|---|---|---|---|
| Belden 3076F | 1 pair, 18 AWG stranded (Type A) | PVC · flexible · sunlight and oil resistant · −40 to +105 °C | Single-device spurs and trunks in the field | 3076F datasheet | Request a quote |
| Belden 3077F | 1 pair, 22 AWG stranded (Type B) | PVC · flexible · UL PLTC, ITC · −30 to +105 °C | Short runs that need a slimmer cable | 3077F datasheet | Request a quote |
| Belden 1334A | 1 pair, 18 AWG stranded | PVC · foil + braid shield · UL CMG · −40 to +105 °C | Single-pair lines in noisy environments | 1334A datasheet | Request a quote |
| Belden 1327A | 2 pairs, 18 AWG stranded | PVC · individually and overall shielded · UL CMG | Carrying several segments in one cable | 1327A datasheet | Request a quote |
| Belden 1337A | 1 pair + 1 conductor, 18 AWG | PVC · 600 V tray cable (TC-ER) | Lines laid in the same tray as power cables | 1337A datasheet | Request a quote |
All Belden Foundation Fieldbus cable part numbers
The tables below list Belden’s current Foundation Fieldbus cables by pair count and construction. Find the code in your specification and write to us; we quote every part number on the list.
Flexible single-pair Foundation Fieldbus cables
| Type | Standard | Aluminium armoured | Steel armoured | Continuous armour |
|---|---|---|---|---|
| 18 AWG · Type A · 300 V PLTC-ER / ITC-ER | 3076F | 123076F | 133076F | 183076F |
| 22 AWG · Type B · 300 V PLTC / ITC | 3077F | — | — | — |
| 22 AWG · high speed | 3078F | 123078F | 133078F | — |
18 AWG multi-pair Foundation Fieldbus cables
| Pairs | PVC · UL CMG | XLPO/TPE · UL CMG | PVC · 600 V tray | XLPO/TPE · 600 V tray | Halogen-free · 600 V tray | Halogen-free (S series) |
|---|---|---|---|---|---|---|
| 1 | 1334A | 2100A | 1337A | 2118A | 2118T · 2118Z | S3076NH |
| 2 | 1327A | 2101A | 1338A | 2119A | 2119T · 2119Z | S1327NH |
| 5 | 1328A | 2102A | 1339A | 2120A | 2120T · 2120Z | S1328NH |
| 8 | 1329A | 2103A | 1340A | 2121A | 2121T · 2121Z | S1329NH |
| 12 | 1330A | 2104A | — | 2122A | 2122T · 2122Z | S1330NH |
| 16 | 1331A | 2105A | — | 2123A | — | S1331NH |
| 20 | 1332A | 2106A | — | 2124A | — | S1332NH |
| 24 | 1333A | 2107A | — | 2125A | — | S1333NH |
| 50 | 1359A | 2108A | — | 2126A | — | — |
16 AWG multi-pair Foundation Fieldbus cables
| Pairs | PVC · UL CMG | XLPO/TPE · UL CMG | XLPO/TPE · 600 V tray | Halogen-free · 600 V tray |
|---|---|---|---|---|
| 1 | 1360A | 2109A | 2127A | 2127T · 2127Z |
| 2 | 1361A | 2110A | 2128A | 2128T · 2128Z |
| 5 | 1362A | 2111A | 2129A | 2129T · 2129Z |
| 8 | 1363A | 2112A | 2130A | 2130T · 2130Z |
| 12 | 1364A | 2113A | 2131A | 2131T · 2131Z |
| 16 | 1365A | 2114A | 2132A | — |
| 20 | 1366A | 2115A | 2133A | — |
| 24 | 1367A | 2116A | 2134A | — |
| 36 | — | 2117A | 2135A | — |
Other fieldbus cables
| Part number | Construction | Feature |
|---|---|---|
| 1335A | 2 conductors, 16 AWG | Foil + braid shield · PVC · UL CM |
| 1336A | 2 conductors, 14 AWG | Foil + braid shield · PVC · UL PLTC |
| SI1341A · SI1342A · SI1343A · SI1344A | SI series | Belden Fieldbus datasheets |
| 50097TPE · 50098TPE | 2 conductors, 1.5 mm² and 2.5 mm² flat cable | AS-Interface bus · TPE jacket |
PVC or XLPO/TPE?
The 13xx series are standard industrial cables with a PVC jacket. The 21xx series has cross-linked polyolefin insulation and a TPE jacket, made for harsher field conditions.
600 V tray-rated Foundation Fieldbus cables
TC and TC-ER rated types are used where the communication cable shares a tray with power cables. Choose codes ending in T or Z where a halogen-free jacket is required.
Foundation Fieldbus cable for PROFIBUS PA
18 AWG Type A Foundation Fieldbus cables are also used on PROFIBUS PA lines. For single-pair PA and PROFIBUS DP cables, see our Belden PROFIBUS cable page.
Armoured versions of Belden Foundation Fieldbus cables
Many of the cables on this page are also available with factory-applied armour. Armour protects the cable against crushing and impact and allows installation without conduit. Each armoured code is shown with its unarmoured base code. The list for all networks is on Belden Armored Data Cable.
| Armoured code | Armour type | Unarmoured base code |
|---|---|---|
| 3077ELS | Steel wire (SWA) | 3077E (base code) |
| 123076F | Aluminium interlock (AIA) | 3076F |
| 123078F | Aluminium interlock (AIA) | 3078F |
| 133076F | Steel interlock (SIA) | 3076F |
| 133078F | Steel interlock (SIA) | 3078F |
| 153076F | Corrugated steel tape (CST) | 3076F |
| 323076F | Aluminium interlock (AIA) | 3076F |
| 753076F | Corrugated steel tape (CST) | 3076F |
| 772118T | Bronze braid | 2118T |
| 772119T | Bronze braid | 2119T |
| 772120T | Bronze braid | 2120T |
| 772121T | Bronze braid | 2121T |
| 772122T | Bronze braid | 2122T |
| 772127T | Bronze braid | 2127T |
| 772128T | Bronze braid | 2128T |
| 772129T | Bronze braid | 2129T |
| 772130T | Bronze braid | 2130T |
| 773076T | Bronze braid | 3076T (base code) |
| 972008Z | Bronze braid | 2008Z (base code) |
| 972118Z | Bronze braid | 2118Z |
| 972119Z | Bronze braid | 2119Z |
| 972120Z | Bronze braid | 2120Z |
| 972121Z | Bronze braid | 2121Z |
| 972122Z | Bronze braid | 2122Z |
| 972127Z | Bronze braid | 2127Z |
| 972128Z | Bronze braid | 2128Z |
| 972129Z | Bronze braid | 2129Z |
| 972130Z | Bronze braid | 2130Z |
| 973076Z | Bronze braid | 3076Z (base code) |
Why Belden?
- From one pair to 50 pairs. Every cable from spur to trunk from one manufacturer.
- Built for harsh environments. Made to withstand temperature extremes, humidity, dust and oil; used outdoors.
- Many shield, armour and rating options. Individually shielded pairs, 600 V tray-rated, halogen-free and armoured types.
- A datasheet for every code. Current manufacturer documents ready for your approval and tender files.
Why PROTEL?
- Authorised Belden distributor. Products come directly from the manufacturer.
- Stock. Commonly used types are kept in stock.
- Cut lengths. You do not have to buy a full reel.
- Selection support. Tell us your line and devices; we recommend a type and explain why.
- Worldwide supply. Shipped from our warehouses in Germany and Turkey.
Frequently asked questions about Foundation Fieldbus cable
What is Foundation Fieldbus cable?
Foundation Fieldbus is the digital field network used in process automation. Its cable is a shielded twisted pair that carries both data and power to field devices.
What is the difference between Type A and Type B Foundation Fieldbus cable?
Type A is 18 AWG and is the standard cable that allows the longest distance. Type B is 22 AWG; it is slimmer and used on shorter lines.
When is multi-pair Foundation Fieldbus cable used?
When several segments run from a junction box to the control room. As each pair is individually shielded, segments do not affect each other.
Can Foundation Fieldbus cable be used for PROFIBUS PA?
Yes. 18 AWG Type A Foundation Fieldbus cables are also suitable for PROFIBUS PA lines.
Do I have to buy a full reel?
No. We supply cut lengths. The part number and the total length are enough.
Request a quote
- If you know the code: the part number, total length and delivery country are enough.
- If you do not: send your application, line length and environment; we recommend the type.
- If you have a specification or BOQ: send it and we will return the matching part numbers.
Technical documents
- Belden Type A and Type B Fieldbus cables bulletin (current link)
- BELDEN Industrial Cables Catalog
- Belden Fieldbus Cables Product Bulletin
- DataBus Selector Guide
- Armor Capabilities
- Free 10-Year Product Warranty
- 3077F technical data (PDF)
- Belden Fieldbus bulletin: armoured types
- 3078F technical data (PDF)
- 3076F technical data (PDF)
- 123076f technical data (PDF)
- 133076f technical data (PDF)
- 183076F technical data (PDF)
- 1334A technical data (PDF)
- 2100A technical data (PDF)
- S3076NH technical data (PDF)
- 1327A technical data (PDF)
- 2101A technical data (PDF)
- S1327NH technical data (PDF)
- 1328A technical data (PDF)
- 2102A technical data (PDF)
- S1328NH technical data (PDF)
- 1329A technical data (PDF)
- 2103A technical data (PDF)
- S1329NH technical data (PDF)
- 1330A technical data (PDF)
- 2104A technical data (PDF)
- S1330NH technical data (PDF)
- 1331A technical data (PDF)
- 2105A technical data (PDF)
- S1331NH technical data (PDF)
- 1332A technical data (PDF)
- 2106A technical data (PDF)
- S1332NH technical data (PDF)
- 1333A technical data (PDF)
- 2107a technical data (PDF)
- S1333NH technical data (PDF)
- 1359A technical data (PDF)
- 2108A technical data (PDF)
- 1360A technical data (PDF)
- 2109A technical data (PDF)
- 1361A technical data (PDF)
- 2110A technical data (PDF)
- 1362A technical data (PDF)
- 2111A technical data (PDF)
- 1363A technical data (PDF)
- 2112A technical data (PDF)
- 1364A technical data (PDF)
- 2113A technical data (PDF)
- 1365A technical data (PDF)
- 2114a technical data (PDF)
- 1366A technical data (PDF)
- 2115a technical data (PDF)
- 1367A technical data (PDF)
- 2116a technical data (PDF)
- 2117a technical data (PDF)
- 1336A technical data (PDF)
- 1337a technical data (PDF)
- 2118A technical data (PDF)
- 1338A technical data (PDF)
- 2119A technical data (PDF)
- 1339A technical data (PDF)
- 2120A technical data (PDF)
- 1340A technical data (PDF)
- 2121A technical data (PDF)
- SI1341A technical data (PDF)
- 2122A technical data (PDF)
- SI1342A technical data (PDF)
- SI1343A technical data (PDF)
- 2124A technical data (PDF)
- SI1344A technical data (PDF)
- 2125a technical data (PDF)
- 2126a technical data (PDF)
- 2127A technical data (PDF)
- 2128A technical data (PDF)
- 2129A technical data (PDF)
- 2130A technical data (PDF)
- 2131A technical data (PDF)
- 2132A technical data (PDF)
- 2133a technical data (PDF)
- 2134a technical data (PDF)
- 2135A technical data (PDF)
Product images and technical information on this page are © Belden Inc. and are used with the manufacturer’s permission. Technical values are taken from the manufacturer’s datasheets; the current datasheet is binding. Source: belden.com
Call us for more information.
Consult PROTEL experts for more details, technical information and routing assistance regarding BELDEN cables.