ER Serisi
EMI Full-Compliance
Analizörü
3
GHz / 26 GHz

LIG Nex1 ER serisi 3 ve 26 GHz
EMI Analizörleri, 10.4 inç büyüklüğünde renkli
ekranları, mükemmel performans özellikleri, zengin
opsiyon çeşitleri ile teknolojinin sunduğu tüm
olanakları, rakiplerine oranla uygun fiyatlarla
birleştiriyor.
ER serisi EMI full-compliance testleri için
tasarlanmıştır.
(EMI pre-compliance testlerinde daha ekonomik çözüm
için, LIG Nex1 LSA serisinin EMI software opsiyonları
bulunmaktadır)
LIG Nex1’s EMI Receiver verifies every EMI standard in
full compliance with CISPR in the frequency range from
3Hz to 3GHz and 3Hz to 26GHz. Experience the LIG Nex1’s
EMI Receiver certified in the fields of EMI Conducted
and Radiated Emission
Desteklendiği
Standartlar
Sivil
standartlar
CISPR11.22
EN55011.55022
VDE0872.0879
ANSI-C63.4
FCC15, 18
EACL1.8
Askeri
standartlar
VG95370.95377
DEF-STAN49.41
GAM-EG13
MIL-STD-461E
Main Uses
Full Compliance for EMI standards (CE, RE)
LIG Nex1’s EMI Receiver is a specialized equipment
designed for EMI full compliance conforming to the
international EMI standard, CISPR16-1-1. The standard pre-selector
for full EMI compliance enhances the reliability of the
test result by removing the interferences among the
signals in the required bands, and precisely measuring the
noise value of the EUT. Also, The standard tracking
generator fulfills alignment of the pre-selector as well
as scalar network analysis, and NSA.
Debugging for EMI R&D, Lab
During the EMI test , users can detect the exact weak
points of the EUT under EMI environment specified on the
EMI standards of each country, and find how to improve the
design by testing its RF characteristics precisely in
Spectrum Analyzer mode. LIG Nex1’s EMI receiver provides
powerful spectrum analyzer performance and personalities
such as Spurious Emission, Phase Noise, TOI, CCDF, and etc.
basically so that users can analyze the exact weak points,
and improve them
EMI Pre-Test for R&D, Manufacturing
In the fields of R&D and manufacturing for RF equipment,
module, parts, and etc., LIG Nex1’s EMI receiver enables
users to save high costs of the EMI Test and debugging
that is regularly fulfilled by the certified EMI lab or
institution on the process of development & manufacturing,
and reduce the trouble shooting time. Also, users can get
the reliable EMI test results under the variously
simulated test environments by changing the field
correction factors using the convenient correction factor
table.
NSA (Normalized Site Attenuation); Environment test
in Chamber
Monitoring the test environment such as antenna, turn
table, and etc. in the test house (Chamber) specified in
CISPR 16-1-4 automatically in real time, and correct it
according to the gathered VSWR data. Users can optimize
EMI test environment in the test house before starting EMI
Test.
Leading in Features:
-
Debugging in
Spectrum Analyzer mode (Scan mode/Spectrum Debugging
Mode)
-
Maximum 6 sub-ranges,
set frequency range, step size, Bandwidth, Measure Time
etc. by ranges
-
Display
traces and limit lines of 3 detectors, Quasi-peak, Peak,
Average simultaneously
-
All
Commercial EMI Standards such as KN, EN, FCC etc based
on CISPR
-
Amplitude
Correction functions: Antenna, Cable, User’s own factors
-
CISPR
verification mode for EMI Lab, Institution
-
X Scale Log/Linear
conversion function
-
Standard
Built-in Pre-selector (14 pre-selection filters) for
precise measurement
-
Standard
Built-in Tracking Generator for Pre-selector alignment
and Normalized Site Attenuation in Test House
-
Standard
Built-in Pre-Amplifier (Gain : 20dB nominal @ 1kHz ~
3GHz)
-
10.4” TFT
Wide Screen LCD
-
System OS:
Windows XP Professional
-
Remote
control : GPIB, RS-232C, LAN Interface (Standard)
-
Labview,
Labwindows, CVI Driver
-
Installable
Printer Driver (XP)
-
Optional
built-in Pre-Amplifier (Gain : 30dB nominal @ 100MHz ~
3GHz)
-
Optional
built-in C/W Signal Generator (1.3GHz/3.3GHz/6.6GHz)
Yeni
ER EMI analizörü serisinin 2 değişik modeli
bulunuyor:
LIG Nex1
ER-30
3 GHz
EMI Analizörü
3Hz - 3GHz, -150dBm dinamik ortalama gürültü seviyesi (DANL),
10Hz RBW, 10.4 inç renkli
ekran, dahili hafıza, 9 markör,
USB, LAN, CD-ROM, RS-232, yazıcı
bağlantısı
LIG Nex1
ER-265
26
GHz EMI Analizörü
3Hz - 26.5GHz, -150dBm dinamik ortalama gürültü seviyesi (DANL),
10Hz RBW, 10.4 inç renkli
ekran, dahili hafıza, 9 markör,
USB, LAN, CD-ROM, RS-232, yazıcı
bağlantısı
ER-30 ingilizce broşür
için ...
(9.32 MB pdf dosyası)
ER-265 ingilizce broşür
için ...
(9.32 MB pdf dosyası)
ER serisi operating manual için ...
(750 kB pdf dosyası)
|

ISA
serisi 3, 8, 13, 26 GHz Spektrum Analizörleri
Full digital signal
processing
Opsiyonel konfigürasyon:
EMI Test & Ölçümleri için
Spektrum Analizörü
EMI Pre-Compliance ölçümleri

-
High Accuracy and Reliability
-
Powerful RF performance, Phase Noise -115
dBc/Hz, DANL -145 dBm/Hz
-
Standard 30 MHz I/Q Demodulation
Bandwidth
-
Remote control via LAN, GPIB, RS-232C
-
S/W extension based on Windows XP OS
-
7" Wide Touch Panel Display
-
Portability based on Light & Compact
design
-
Standard Removable hard disk
-
Batarya ile çalışabilme (opsiyon)
ISA series signal analyzer basically
includes wide band digitizer. It is optimized for
analyzing various wireless communication systems which has
complicated and wide band
characteristics.
EMI option:
The EMI Measurement S/W for pre-compliance test in
accordance with the international EMI commercial standards,
CISPR16-1-1, KN, EN, FCC. This application enables the
users to pre-test the EMI characters and detect some
problems while developing all kinds of electric devices or
appliances. The users can debug the problems in advance
before they apply for an official certificate at EMI Labs.,
and save the development cost & time. In addition, an
optional EMI Total solution PC s/w, ETS2008 provides the
users with a powerful tool for EMI measurement along with
its various user-friendly functions. This ETS2008 can
control other equipment like a turn table, antenna master,
and helps users the gather the data, and manage them
easily.
ingilizce
teknik broşür (14.8 MB)
ISA serisi spektrum
analizörleri kullanım klavuzu (1.54 MB)
EMI opsiyonu kullanım klavuzu (1.23 MB)
|